Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
26 Cards in this Set
- Front
- Back
what is the NFPA standard on selection, care, and maintenance of the open circuit SCBA
|
1852
|
|
what law governance PASS devices
|
chapter 435, section 9
ensure that the past device assigned to were available to be assigned to an individual user be inspected at the beginning of each duty. And before each use |
|
what times can SCBA inspection reports be entered?
|
Starting at 11:30 AM
Battalion Chiefs as early as 10:30 AM |
|
who's responsible for logging in the fire net and completing inspection of the SCBA each shift?
|
Each individual user
|
|
who is responsible for inspection records of those SCBA's on in-service unit that are not assigned to an individual user
|
the fire specialist or acting fire specialist
this includes air carts, regulators and HM escape packs |
|
each SCBA that is not assigned to an individual or in-service unit will be inspected when?
|
Once a week and must be entered between Monday and Friday
|
|
who is responsible their inspections are done in accordance with this policy in operations and in non-operations
|
operations: company officers
non-operations: designated staff supervisor |
|
who collects and maintains the inspection records
|
the air shop personnel
|
|
what cylinder pressure is considered fu? I
|
4000 PSI or above
replace is below 4000 PSI |
|
what direction you turn the cylinder valve to turn the tank on?
|
Counterclockwise
|
|
was automatic mode for pass device
|
this is when the device is not alarming but is set to alarm if lack of motion is detected
|
|
why might the Vibralert alarm not actuate when opening the cylinder valve
|
it the air saver/dining switch has not been depressed prior to opening the cylinder valve and therefore the air is flowing freely
|
|
how far should you rotate the purge valve to test it
|
half turn counterclockwise
|
|
how long does it take for the air pack to go into pre-alarm mode?
|
20 seconds
|
|
how many seconds after prealarm mode does it take for the SCBA to enter full alarm mode?
|
12 seconds
|
|
how do you check battery condition of an SCBA?
|
When the unit is off, press and hold yellow reset button on console for 2 seconds. A green light on the console indicates good batteries, a red light indicates bad batteries
|
|
describe full alarm mode on SCBA
|
loud, almost continuous three tone chirp
flashing red signal lights on back frame and remote gauge console |
|
when the Vibralert is alarming, what is displayed on the HUD
|
a red light flashing 10 times per second
|
|
if a 15 second beep sequence with green flashing lights is heard from the sensor module, what does that mean
|
there is residual air in the system that needs to be bled
|
|
working you find the inspection record form?
what do you do if the system is down? |
Under the fire depot page on fire net
Try to enter it later in the shift, is still down at 11:30 AM, record the inspection including serial numbers and points of failure in the company Journal |
|
who receives notification of the inspection log?
|
Battalion Chiefs will be with notified of units who have not completed their inspections on the current shift and will pass it on to the company officer
|
|
will you hear if the pass device has a low battery
|
the sensor module will sounded chirped every 2 seconds. the green lights on the control module will go out
a red lights will appear on the far right of HUD – a dot, not a square |
|
describe HUD lights and pressures they represent
|
two green lights equals 3000 PSI
one green light equals 2000 3000 PSI one flashing amber light equals 1000 – 2000 PSI blinking red light equals less than 1000 PSI |
|
how many and what type of batteries are used in the PASS device
|
PASS device requires three new C cell batteries Energizer industrial alkaline silver
|
|
what we see when you put new batteries into the PASS device
|
the back frame will flash blue once
|
|
when SCBA, PASS device or face piece needs repair or servicing:
|
1 remove from unit and Mark with repair tech. Fill out an air shop repair request form on the StarNet link
2 only call air tech after hours if deficiency reduces number of SCBA's below staffing |