194 Cards in this Set
- Front
- Back
How many AFFF stations are there? |
20 |
|
What is the capacity of the AFFF tanks at the stations? |
600 gallons |
|
What is the ratio AFFF concentrate to water? |
94% water 6% AFFF |
|
What is the capacity of the AFFF fill tanks in the hangar bay? |
3900 |
|
How many repair lockers ate there? |
10 |
|
How many units lockers are there? |
20 |
|
Which repair lockers are on the 2nd deck and where are they located? |
Rep 2-fwd port-supply male berthing Rep 3- aft port-reactor lounge Rep 4- forward port- medical p-way Rep 5-midship-aft mess decks |
|
Which repair lockers are on the main deck and where are they located? |
1A - Hangar bay 3 - by waste 1B - hangar bay 2 - port side 1F - hangar bay 1 - port side |
|
Which repair lockers are on the main deck and where are they located? |
7A- Aft - starboard side 7B- midship- stud side 7F- Fwd - port side |
|
What size SCBA bottles do we have on-board? |
30 & 45 min |
|
What is the minimum PSI an SCBA can be in order to use it? |
4000 PSI |
|
What locker positions use the 30 minute bottle? |
Investigator, repair electrician, & boundary man outside of the primary smoke boundary. |
|
What locker positions use the 45 minute bottles? |
Attack team |
|
What agents are used to combat an A fire? |
Water,CO2, AFFF |
|
What agents are used to combat a class B fire? |
AFFF, PKP, HFP, APC |
|
What agent do you use combat a class C fire? |
CO2 |
|
How do you combat a class D fire? |
Jettison |
|
Who is the Damage Control Officer? |
Cheng, CMDR Groom |
|
How do you operate a PKP bottle? |
-Pull pin -Activate CO2 cartridge -Spray in a sweep motion. |
|
How many size PKP bottles do we carry on-board? |
2 |
|
What are the two sizes of PKP bottles? |
18Lb and 27 Lb |
|
How far does the 18lb PKP bottle discharge? |
19ft |
|
How far does the 27 Lb PKP bottle discharge? |
21ft |
|
How do you operate a CO2 bottle? |
-Pull pin -Ground the bottle -Hold the bottle by the horn -Squeeze the lever |
|
How far does the CO2 bottle discharge? |
4-6 ft from the horn |
|
What is a box fan rated at? |
3,200 CFM |
|
What is the ram fan rated at? |
2,000 cfn |
|
What types of dewatering equipment do we use? |
- P-100 -S-type -Peri-jet -ESP -Bucket and swabs |
|
What powers the P-100? |
JP-5 |
|
What powers the ESP? |
440V |
|
What types of pipe patches do we use on board? |
-Soft patch -Jubilee -EWARP -Banding |
|
What does EWARP stand for? |
Emergency Water Activated Repair Patch |
|
What is the max PSI for the soft patch? |
150 PSI |
|
What is the max PSI for a soft patch? |
150 PSI |
|
What is the max PSI for the EWARP?what is the max PSI for a Jubilee patch? |
Upwards of 100PSI |
|
What is the max PSI for EWARP? |
150 PSI |
|
Who serves as the ITT leader & DCTT team Leader? |
XO |
|
Name 3 types of shoring. |
H,I ,& K |
|
Which shore is the strongest? |
I |
|
Why is I type the strongest? |
It applies direct pressure. |
|
What are the two sizes of various nozzle? |
1- 1/2 & 2-1/2 |
|
What is the required Manning of a 1 1/2 inch hose. |
3-5 |
|
What is the required Manning of a 2 1/2 inch hose? |
5-7 persone |
|
How many BDS stations do we have? Name them. |
-6 -Forward BDS -Forward auxiliary BDS -Amidship BDS -Aft BDS -Aft auxiliary BDA -Flight deck BDS |
|
How many positions in the repair party are there? Name them. |
-11 -Repair party leader,team leader, scene leader, phone talker, investigator, electrician, nozzle man, hose-man, plug man, access man, overhaul man. |
|
What is indicated by yellow, purple, light green,and dark purple. |
Yellow - gasoline Purple - JP-5 Light green - oxygen Dark purple - refrigerant |
|
What are the basic material conditions of readiness? |
X-ray, yoke, and zebra. |
|
What are the special classifications of material conditions? |
William, circle William, circle zebra, dog zebra, circle x-ray, and circle yoke. |
|
What type of fire main systems do we have on-board? |
Composite system of 2 twelve inch mains. |
|
How many fire pumps are on board? |
26 |
|
What's the fire pumps capacity? |
1,000 gpm |
|
What's the fixed system that fights fires in the galley? |
APC, Gaylord system. |
|
What NSTM is considered the DC Bible? |
NSTM 555 |
|
What type of gas masks do we carry on board? |
MCU - 2P |
|
What canister is used in conjunction with the mcu-2p gas mask? |
C-2 Canister |
|
What paper detects chemical agents in the liquid form? |
M-8 paper |
|
M-256 kit detects agents in what form? |
Vapor |
|
What agents does M-8 paper detect.? |
Nerve and blister |
|
What agents does M-256 kit detect? |
Nerve, blood, and blister. |
|
What color does M-8 paper turn into when it the text in agent |
Red, green, and yellow |
|
What suit do you done during a CBR attack |
JSLIST |
|
What does JSLIST stand for? |
Joint service lightweight integrated suit technology |
|
What is the shelf life of the JSLIST |
5 years |
|
What is the casualty communication circuit? |
X40J |
|
What is another name for the X40J? |
Pumpkin reel |
|
How many co2 hose reel do we have on board |
32 |
|
How many overboard discharge connections do we have |
32 |
|
What is the purpose for overboard discharge connections |
To pump overboard in case of flooding inside the ship |
|
Where are the overboard discharge connections located |
On the 2nd deck |
|
Who is permission do you need to come over the side using the overboard discharge connections |
The CO |
|
What's another name for the second deck |
The DC deck |
|
What's another name for the 03 level |
The gallery deck |
|
How many catapult do we have |
4 |
|
How many catapult can we fire simultaneously |
Two |
|
How many gallons of feed water do the catapult hold |
7000 |
|
What is the minimum main steam supply pressure needed to launch in aircraft |
450 PSI |
|
How much feed water is required to perform a catapult shot |
250 gallons |
|
What is the crossfire suppression system |
It is steam used to smother the fire in the trough |
|
What size risers do we use to Supply the catapult |
To and 10 in risers |
|
How many AC units do we have |
6 |
|
What is the AC capacity |
800 ton |
|
How many refers do we have |
Five |
|
What is the reefer capacity |
Seven ton |
|
What is the primary purpose of the AC |
Shoe keep electronic equipment cool |
|
What is the secondary purpose of the AC |
Crew comfort |
|
What is the TXV |
Thermal expansion valve |
|
How many faces are there in the refrigeration cycle and what are they |
For cycles compression condensation expansion and evaporation |
|
What type of refrigerant do we use on board |
Are 134 Alpha |
|
How many Stillwater loops do we have on board |
Forward, mid-ship, and aft Island loop |
|
What is the primary function of the water regulating valve |
To maintain constant refrigeration condensate pressure by controlling the amount of water flowing through the condenser |
|
How many O2 into plants do we have |
2 |
|
Where are the 02 into plants located |
HB 1 port side and HB 3 starboard side |
|
What are the uses of o2 |
Pilot breathing air medical and dental |
|
What's are the uses of N2 |
Inflated aircraft tires, re-boiler lay up, and Pilot ejection seat |
|
What are the two things you never wants to come and contact with o2 |
Petroleum products and open flames |
|
What percentage of breathable air is oxygen in what percentage is nitrogen |
21% oxygen 78% nitrogen |
|
What temperature does oxygen liquify |
Minus 295 degrees |
|
What type of nitrogen do we produce on board |
Gaseous nitrogen |
|
What are the advantages of gases nitrogen |
Does not expand Orkin track deep you temperature change and is inert |
|
How many list control tank do we have |
10 |
|
Where are the list control tank located |
From friends 96 to 148 between 4th and 6th deck |
|
How many list control pumps do we have |
2 |
|
How much fluid can the list control pump transfer in 1 minute |
1800 gallons |
|
Which list tanks on the ship have more capacity |
The ones on LaPorte side |
|
What is our standard list during flight operations |
A 1/4 to 1/2 degree to Port |
|
Where are the list control pumps located |
For alpha shaft alley |
|
What other ways can we adjust the ship's list |
Move fuel, move aircraft, move tilly |
|
What do we use to fill the list control tanks |
Portable water or see water in an emergency |
|
What does VC HT stand for |
Vacuum collection holding and transfer |
|
How many VC HT plants do we have |
2 |
|
How many doctors vacuum eductor pumps are in each be VCHT plant |
10 |
|
How many nautical miles out do we need to be to pump over the side |
Three |
|
What type of toxic gas is produced during a sewage spill and what does it smell like |
H2 s in it smells like rotten eggs |
|
How many moles of steering are there |
Five |
|
What are the five modes of steering |
Automatic, follow up, non follow up, trick wheel, emergency |
|
Where is the automatic mode controlled from |
Bridge, pilot house |
|
Name the watches station in aft steering during normal operation |
Two Helmsman, steering gear operator, steering gear electrician |
|
Name the washer station in a steering during restricted maneuvering. |
Helm safely officer, master Hellman, operator, and electrician |
|
What what is the maximum degree of the flexion of the runner |
35 degrees Port or starboard 30° under normal conditions |
|
What are the my nuvaring control circuit |
One JV and x1 JV cross connected |
|
What is the restrictive maneuvering doctrine for |
Plan when maximum propultion and uninterrupted electrical power are vital for safety of the ship |
|
What is the maximum speed of runner movement |
2 1/3 degree per second |
|
What is the rudder speed for emergency steering |
1/8 degree per second |
|
What is the purpose of the degaussing |
To reduce the magnetic signature of the ship |
|
How many degaussing coils do we have |
4 |
|
What are the four degaussing coils |
A,M,FP-QP, FI-QI |
|
Where is the remote control panel for the degaussing system located |
Bridge pilot house |
|
What are the ratings for the ship service turbine generators |
4160 volts 60 hurts 1388 amp 8 mega Watts |
|
What are the ratings for the emergency diesel generators |
4160 volts 60 herts 347amps 2 mega Watts |
|
What is 60 Hertz power used for |
General power and lighting |
|
What is 400 hurts power used for |
Electronic equipment, radar, radio, missile launching system |
|
How many aircraft elevators do we have |
4 |
|
What is the surface area of each elevator |
4000 square feet |
|
How many weapons elevators do we have |
9 six Lower stage 3 upper stage |
|
What are the responsibilities of reactor department |
-Create steam for propultion, electricity generation, catapult, And, reboiler services -Make portable water - pollution abatement - hi pressure and ship service air generation |
|
How many reactor are on board |
2 |
|
What is RX scram |
Emergency shut down of a reactor |
|
What does RX critical mean |
The reactor is operating at a steady power level |
|
How many re boilers are on board |
2 |
|
What are the locations of the re boilers |
1a shaft alley and 4b shaft alley |
|
What are the service loads provided by the re boilers |
-50 lb service steam. -100 lb laundry steam. -Distilling plant air electors -Alot -Mlop |
|
What is CSC and what does it do |
Catapult supervisor control regulates the rate of refill of the catapult steam accumulators |
|
How many HPACS's are on board |
4 |
|
State location of the ship's HPAC's |
1 and 2 = 1MMR 3 and 4 = 2 MMR |
|
How many ships service air compressors are on board |
3 |
|
State the locations of the ship service air compressors |
1 =1MMR 2= 2 reactor auxiliaries 3= 2MMR |
|
What is the purpose of the ship's Distilling plants |
Convert see water in 2 portable water and reactor plant makeup water |
|
State the locations of the ships du's |
1 and 2= 1 MMR 3 and 4= 2MMR |
|
What is the maximum amount of water produced by one Du per day |
100,000 gallons |
|
State the purposes of the ship's emergency diesel generator |
To provide electrical power to reactor fill pumps and provide emergency electrical power to the boat in case of casualty |
|
State the locations of the ship service turbine generators |
one and two- main machinery room 1 3 and four number- two main machinery room |
|
State the purpose of the ship's coolant turbine generators |
Uses steam to generate electricity for the ship's reactor coolant pumps |
|
State the locations of the coolant turbine generators |
1 and 2 in 1 reactor auxiliary room three and four in 2 reactor auxiliary room |
|
Who is overall in charge of reactor department |
The reactor officer |
|
Who is the reactor officer |
Commander Concannon |
|
What is reactor controls division responsible for |
Maintenance in operation of reactor electronic equipment |
|
What rate is reactor control division composed of |
ET |
|
What is reactor electrical division responsible for |
Maintenance in operation of reactor electrical equipment |
|
What rate is reactor electrical division composed of |
E m |
|
What is reactor laboratories divisions responsible for |
Maintaining reactor plant, steam plant, And reboiler water chemistry |
|
What rate is reactor laboratories division is composed of |
Mm |
|
What is reactor mechanical divisions responsible for |
Madison operation of reactor plant machinery |
|
What rate is reactor mechanical composed of |
Mm |
|
What is reactor propulsion division responsible for |
Maintenance in operation of propulsion equipment as well as other equipment located in the main machinery room |
|
What rate is RP division composed of |
Mm |
|
What is reactor auxiliary division responsible for |
Maintenance in operation of the emergency diesel generators |
|
What rate is reactor auxiliary division composed of |
En and mm |
|
What does TLD stand for |
Thermo Luminescent Dosimeter |
|
What is the purpose of a TLD |
Measures the amount of radiation the wearer is exposed to |
|
State the propultion plant supervisory watch standers and they're watch locations |
Engineering officer of the watch-DCC Load dispatcher - DCC Propulsion plant watch officer- #1 or #2 enclosed operating station Propulsion plant watch supervisor- #1 or #2 reactor plant Chief reactor watch- #1 or #2 reactor auxiliaries room Chief machinery operator- #1 or #2 main machinery room |
|
State the purpose of the main engines |
Convert thermal energy from steam into mechanical work to move the ship |
|
How many main engines do we have on board |
4 |
|
State the locations of the main engines |
One and four -1 MMR Two and three -2 MMR |
|
What is the maximum RPM the shaft can rotate at |
171 RPM |
|
What is the purpose of the main reduction gear |
To reduce hi speed rotation of turbines into slower speed of shafts |
|
What was the first nuclear power vessel |
USS Nautilus |
|
What was the first nuclear power surface ship |
USS Long Beach |
|
What was the first nuclear powered aircraft carrier |
USS Enterprise |
|
Who is the father of Naval nuclear power |
Hyman G. Rickover |
|
State the advantages of nuclear power vice fossil fuels |
Let's pollution and longer. Between reef fueling |
|
What is the fuel used in our actors |
Uranium 235 |
|
Explain how nuclear reaction produces usable energy |
Uranium 235 releases neutrons which collide with water molecules making heat energy. |
|
Which reactor design is used on board |
A4W |
|
What does ORSE stand for |
Operational reactor safeguard examination |
|
What is ORSE |
Annual inspection of reactor department to ensure safe operation of the reactors |
|
What are the four purposes of the ship store a float |
Crew comfort Provide service for day to day living Source of profit for MWR Promote good morale |
|
What year was the Navy cash program established |
1988 |
|
What is the purpose of the Navy cash program |
To eliminate the need for sailors in Marines to carry cash on board |
|
What is the maximum level of money that could be transferred from Navy cash strip |
$1,000 |
|
What is the maximum daily amount that could be transferred from a financial institution to the Navy cash card |
$400 |
|
What is the maximum amount that can be used from the chip before re-inserting your card into a ships ATM machine as security device |
$25 |
|
If you lose your Navy cash card who do you report it to |
Disbo |
|
What is the acronym BDFA |
Basic daily food allowance |
|
Describe BDFA |
Set quantity of food to provide a adequate diet for one. |