• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/30

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

30 Cards in this Set

  • Front
  • Back
Which of the following is one of the primary problems associated
with incandescent light bulbs?
Aging
Which of the following devices prevents increased current flow
as electric-discharge lamps heat up?
Ballast
What is the main drawback of
the older type of sodium lights?
Poor color quality
The base of high-intensitydischarge lighting should be maintained below what maximum temperature?
2. 210°F
Which of the following procedures will reduce the stroboscopic effect produced by AID lights?
Connect adjacent lamps to different power phases
High-intensity mercury-vapor and metal-halide lamps should NOT be
operated if the outer globe is broken, punctured, or missing.
True
What special precautions must be taken if HID equipment is installed in a series wiring
circuit?
Provide protection from high
voltages that occur during hot restarts
Fluorescent lamps use what type of interior coating to give off
light?
Fluorescent lamps use what type of interior coating to give off
light?
Ballasts provide which of the following functions?
Limit current flow through the lamp
. Provide correct voltage to the lamp
Provide power factor correction
A thermally protected ballast
approved by Underwriter's Laboratories is classified as
. Class P ballast
Which of the following devices are used with lamp fixtures to change the quality of light
produced
1. Reflectors
2. Lenses
When HID lighting fixtures are
mounted on poles, the ballasts should be mounted
1. at the base of each pole
A constant-current regulator is sized to provide 6.6 amperes of
current to a lighting circuit. If higher amperage is required, which of the following devices are used to increase the current capacity?
2. Autotransformers
Which of the following devices
prevents a lamp failure from interrupting the entire series
circuit?
Film-disk cutout
When you are running conductors over a great distance to supply
streetlights in a parallel circuit, which, if any, of the following is a DISADVANTAGE?
Excessive voltage drop
If both conductors of a series lighting circuit are installed
on the same pole, the system is known as what type of circuit?
Closed-loop
Insulators that are installed on series streetlighting circuits
should be of what color to distinguish them from those on other distribution circuits?
White
On series streetlighting circuits, what size of hard-
drawn copper conductor is normally used?
No. 6 AWG
Which of the following factors determines the output voltage rating of a transformer
supplying streetlighting in a parallel circuit?
Voltage rating of the individual lamps
What is the basic principle involved in the operation of
a constant-current regulator?
A balanced lever reacts to
current flowing through its springs
Constant-current regulators may be overloaded to what percent
without damage to the regulator?
10
Which of the following devices may be installed to relieve constant-current transformers that are slightly overloaded?
Booster transformers
To supply 140 1,000-lumen, 6.6-ampere, straight-series lamps, you would need a regulator of what size?
10 kW
When the width of a roadway approaches two mounting heights wide, what mounting arrangement
should be used?
Staggered
Which of the following statements best describes the information that can be obtained
from a utilization curve?
he amount of usable light
that actually strikes the area to be lighted
Which part of the manufacturer's literature shows the magnitude
and direction of illumination at any point on the roadway
surface?
sofootcandle curve
The factor used in lighting
calculations to compensate for gradual losses of illumination is known as what kind of factor?
Maintenance
Which of the following factors influence(s) the selection of
the luminaire?
udget constraints 2. Availability 3. Stock levels in the supply
What must be calculated before the coefficient of utilization
can be determined?
Amount of wasted light on
the street side 2. Amount of wasted light on
the house side
The uniformity of illumination is expressed in terms of a ratio
of
maximum fc/minimum fc