BOYLE'S LAW DEALS WTH THE RELATIONSHIP BETWEEN: |
PRESSURE AND VOLUME
|
|
CHARLE'S LAW DEALS WTH THE RELATIONSHIP BETWEEN:
|
VOLUME AND TEMPERATURE
|
|
GAY-LUSSAC'S LAW DEALS WTH THE RELATIONSHIP BETWEEN: |
PRESSURE AND TEMPERATURE
|
|
HENRY'S LAW DEALS WTH THE RELATIONSHIP BETWEEN: |
PRESSURE AND DISSOLVED GAS
|
|
WHO IS KNOWN AS THE FATHER OF PRESSURE PHYSIOLOGY?
|
BERT
|
|
WHO CREATED THE FIRST SET OF DECOMPRESSION TABLES?
|
HALDANE
|
|
WHO PROVED OXYGEN TRANSPORT BY PLASMA?
|
BOEREMA
|
|
WHICH ONE OF THE FOLLOWING IS NOT EQUIVALENT TO THE OTHERS? |
29.4 PSI
|
|
OXYGEN IS AN INERT GAS. |
FALSE
|
|
TO CONVERT FARENHEIT TO RANKINE YOU WOULD:
|
ADD 460
|
|
IN A HEALTHY PERSON, THE NORMAL ARTERIAL PO2 IS APPROXIMATELY:
|
100 MMHG
|
|
SYMPTOMS OF PULMONARY OXYGEN TOXICITY INCLUDE ALL OF THE FOLLOWING EXCEPT:
A. SEIZURE B. DIFFICULTY BREATHING C. COUGH D. SUBSTERNAL BURNING |
SEIZURE
|
|
A PATIENT CANNOT HAVE CNS OXYGEN TOXICITY AT LESS THAN 2.0 ATA PRESSURE.
TRUE / FALSE |
FALSE
|
|
THE HIGHEST DOSE OF OXYGEN THAT WE WILL GIVE A PATIENT IS :
|
100% AT 3ATA PRESSURE
3 ATMOSPHERES OF OXYGEN 2280 MMHG |
|
NITROGEN NARCOSIS CAN OCCUR AT A PN2 OF 1000MMHG.
TRUE/FALSE |
TRUE
|
|
FACTORS THAT TEND TO RESOLVE BUBBLES INCLUDE ALL OF THE FOLLOWING EXCEPT:
|
DECREASED HYDROSTATIC PRESSURE
|
|
THE TIME IT TAKES FOR HALF OF THE NITROGEN IN A TISSUE TO BE OFF GASSED IS CALLED A TISSUE HALF TIME. |
TRUE
|
|
MODERN DECOMPRESSION TABLES USE HALDANE'S 2 TO 1 RULE.
TRUE/FALSE |
FALSE
|
|
TOTAL BOTTOM TIME INCLUDES DESCENT TIME |
TRUE
|
|
DEPTH OF A DIVE IS : |
THE GREATEST PRESSURE REACHED DURING A DIVE
|
|
RNT IS:
|
ZERO AFTER 12 HOURS
|
|
TYPE I DECOMPRESSION SICKNESS S ALWAYS TREATED WITH HYPERBARIC OXYGEN: |
FALSE
|
|
AGE CAN BE CAUSED BY A BREATH-HOLDING ASCENT.
TRUE/FALSE |
TRUE
|
|
CAGE MEANS:
|
CEREBRAL ARTERIAL GAS EMBOLIISM
|
|
PFO MEANS:
|
PATENT FORAMEN OVALE
|
|
____________ BAROTRAUMA |
MIDDLE EAR
|
|
WHICH OF THE FOLLOWING IS NOT A THERAPEUTIC MECHANISM OF HYPERBARIC OXYGEN?
|
VASODILATION
|
|
IF THE DOSE OF OXYGEN IS TOO HIGH, HYPERBARIC OXYGEN CAN CAUSE REPERFUSION INJURY.
TRUE/FALSE |
FALSE
|
|
US NAVY TREATMENT TABLE 5 IS USED TO TREAT AGE.
TRUE/FALSE |
FALSE
|
|
US NAVY TREATMENT TABLE 6 IS USED TO TREAT NEUROLOGIC DCS.
TRUE/FALSE |
TRUE
|
|
HYPERBARIC OXYGEN IS ADJUNCTIVE TO THE TREATMENT OF CO POISONING. |
FALSE
|
|
IF A PATIENT BREATHES OXYGEN AT 1 ATA PRESSURE, THE HALF LIFE OF CARBON MONOXIDE IS:
|
23 MINUTES
|
|
CLOSTRIDIAL MYONECROSIS IS TREATED AT 2.0 ATA PRESSURE TO MINIMIZE THE RISK OF CNS OXYGEN TOXICITY.
TRUE/FALSE |
FALSE
|
|
THE HYPERBARIC TREATMENT PROTOCOL FOR ORN IS: |
30 PRE-OPERATIVE AND 10 POST-OPERATIVE TREATMENTS
|
|
A DUOPLACE CHAMBER IS:
|
A MULTIPLACE CHAMBER
|
|
OXYGEN CYLINDERS ARE COLOR CODED GREEN IN THE US.
TRUE/FALSE |
TRUE
|
|
NITROGEN CYLINDERS ARE COLOR CODED BLACK IN THE US. |
TRUE
|
|
AIR CYLINDERS ARE COLOR CODED BLACK AND GREEN IN THE US.
TRUE/FALSE |
FALSE
|
|
PRESSURE VESSEL CONSTRUCTION STANDARDS ARE PUBLISHED BY :
|
ASME
|
|
A BIBS IS USED TO:
|
DELIVER A BREATHING GAS
|
|
PHYSIOLOGIC MONITORING LEADS AND COMMUNICATIONS ARE ALLOWED INSIDE A MONOPLACE CHAMBER.
TRUE/FALSE |
TRUE
|
|
IF AN IV IS ADMINISTERED INSIDE A MULTIPLACE CHAMBER, GLASS BOTTLES ARE PREFERRED BECAUSE THEY ARE NOT AFFECTED BY BOYLE'S LAW. |
FALSE
|
|
A PATIENT INSIDE THE MONOPLACE CHAMBER DOES NOT NEED TO BE GROUNDED IF THE CHAMBER IS GROUNDED.
TRUE/FALSE |
FALSE
|
|
THE OXYGEN PERCENTAGE IN A MULTIPLACE CHAMBER SHOULD NOT EXCEED:
|
23.5%
|
|
A FSS IS USED TO: |
EXTINGUISH A FIRE
|
|
THE TREATMENT FOR PNEUMOTHORAX IS:
|
CHEST TUBE
|
|
PREGNANT FEMALES CANNOT RECEIVE HYPERBARIC OXYGEN TREATMENTS.
TRUE/FALSE |
FALSE
|
|
HYPERBARIC OXYGEN WILL NORMALLY CAUSE A DIABETIC PATIENT'S BLOOD GLUCOSE TO DROP. |
TRUE
|
|
AN ABI OF 1.O5(105%)INDICATES EXCELLENT BLOOD FLOW AT THE ANKLE.
TRUE/FALSE |
TRUE
|
|
CAPILLARY REFILL CAN BE MEASURED WITH A TCP02 MONITOR |
FALSE
|
|
TCPO2 MEASURES:
|
TISSUE OXYGEN LEVELS
|
|
ALL OF THE FOLLOWING WILL RAISE TCP02 VALUES EXCEPT:
|
PLANTAR SKIN
|
|
ALL OF THE FOLLOWING WILL LOWER TCPO2 VALUES EXCEPT: |
LEAVING THE PATIENT'S LIMBS UNCOVERED
|
|
WHILE BREATHING OXYGEN AT 2 ATA PRESSURE A PATIENT'S TCPO2 VALUE SHOULD BE ABLE TO REACH.
|
1000 MMHG
|