HOT WATER HEATING SYSTEMS PRODUCE HEAT MORE CONSISTENTLY THAN STEAM HEATING SYSTEMS.
|
TRUE OR FALSE
|
|
HOT WATER HEATING SYSTEMS REQUIRE LESS WATER THAN STEAM HEATING SYSTEMS.
|
TRUE OR FALSE
|
|
THE NATURAL CIRCULATION HOT WATER HEATING SYSTEM USES CIRCULATING PUMPS TO TRANSPORT WATER IN THE SYSTEM.
|
TRUE OR FALSE
|
|
WATER BECOMES LIGHTER AS IT IS HEATED.
|
TRUE OR FALSE
|
|
THE NATURAL CIRCULATION HOT WATER HEATING SYSTEM USES A COMPREESSION TANK TO ABSORB PRESSURE CHANGES
|
TRUE OR FALSE
|
|
NATURAL CIRCULATION HOT WATER HEATING SYSTEMS ARE COMMONLY USED IN LARGE CONTEMPORARY BUILDINGS.
|
TRUE OR FALSE
|
|
FLOOR-MOUNTED CIRCULATING PUMPS ARE USED IN SMALL PLANTS.
|
TRUE OR FALSE
|
|
LINE-MOUNTED CIRCULATING PUMPS OPERATE INTERMITTENTLY, DEPENDING ON PLANT REQUIREMENTS.
|
TRUE OR FALSE
|
|
THE FORCED CIRCULATION HOT WATER HEATING SYSTEM IS VENTED TO THE ATMOSPHERE.
|
TRUE OR FALSE
|
|
THE AQUASTAT CONTROLS THE STARTING AND STOPPING OF THE BURNER ON A HOT WATER BOILER.
|
TRUE OR FALSE.
|
|
THE FLOW CONTROL VALVE PREVENTS NATURAL CIRCULATION WHEN WATER IS NOT PUMPED IN THE SYSTEM.
|
TRUE OR FALSE
|
|
THE PRESSURE-REDUCING VALVE IS USED TO PREVENT OVER EXPRESSURE OF WATER SUPLIED TO THE EXPANSION TANK.
|
TRUE OR FALSE
|
|
DIVERTER FITTINGS ARE USED TO VENT AIR FROM THE HEATING UNITS.
|
TRUE OR FALSE
|
|
STOP VALVES BEFORE AND AFTER THE PRESSURE-REDUCING VALVE ALLOW SERVICING OF THE PRESSURE-REDUCING VALVE.
|
TRUE OR FALSE
|
|
THE THREE-WAY MIXING VALVE BLENDS WATER RETURNING FROM THE HEATING UNITS WITH SUPPLY WATER FROM THE BOILER.
|
TRUE OR FALSE
|
|
ALL BOILERS ARE MANUFACTURED IN CONFORMANCE WITH SECTION I OR IV OF THE ASME BOILER AND PRESSURE VESSEL CODE
|
TRUE
FALSE |
|
AN AQUASTAT CONTROLS THE BURNER BY SENSING STEAM PREASSURE IN A HOT WATER BOILER.
|
TRUE
FALSE |
|
THE STRAINER IN THE PRESSURE-REDUCING VALVE SHOULD BE INSPECTED PERIODICALLY FOR SCALE FORMATION.
|
TRUE
FALSE |
|
THE COMPRESSION TANK IS NORMALLY FULL OF WATER TO FEED INTO THE BOILER DURING A LOW WATER CONDITION.
|
TRUE
FALSE |
|
THE SAFETY RELIEF VALVE SHULD BE OCATED ON THE HIGHEST PART OF THE BOILER
|
TRUE
FALSE |
|
SAFETY RELIEF VALVES SHOULD BE MANUALLY TESTED EVERY 30 DAYS AS RECOMMMENDED BY THE ASME CODE
|
TRUE
FALSE |
|
SAFETY RELIEF VALVES SHOULD DISCHARGE INTO THE RETURN LINE FEEDING INTO THE CIRCULATING PUMP.
|
TRUE
FALSE |
|
A TEMPERATURE-PRESSURE GAUGE INDICATES TEMPERATURE IN THE COMPRESSION TANK.
|
TRUE
FALSE |
|
HYDROSTATIC PRESSURE IS EXPRESSED IN POUNDS PER SQUARE INCH (PSI).
|
TRUE
FALSE |
|
AIR CONTROLS ARE USED TO ALLOW WATER TO DRAIN FROM THE COMPRESSION TANK IN A FORCED CIRCULATION HOT WATER HEATING SYSTEM.
|
TRUE
FALSE |
|
AIR REMOVED FROM THE BOILER WATER IS DIVERTED TO THE COMPRESSION TANK IN A FORCED CIRCULATION HOT WATE HEATING SYSTEM.
|
TRUE
FALSE |
|
AIR REMOVED FROM THE BOILER WATER IS DIVERTED TO THE COMPRESSION TANK IN A FORCED CIRCULATION HEATING SYSTEM
|
TRUE
FALSE |
|
AN AQUASTAT COMMONLY HAS A TEMPERATURE DIFFERENTIAL PRESET BY THE MANUFACTURER.
|
TRUE
FALSE |
|
THE AQUASTAT TEMPERATURE DIFFERENTIAL SETTING CONTROLS THE STARTING AN DSTOPPING OF THE CIRUCLATING PUMP.
|
TRUE
FALSE |
|
TWO DIVERTER FITTINGS MAY BE REQUIRED FOR HEATING UNITS ABOVE THE SUPPLY LINE WHERE RESISTANCE TO CIRCULATION IS HIGH.
|
TRUE
FALSE |
|
HOT WATER HEATING SYSTEMS REQUIRE SPECIAL HOT WATER BOILER ACCESSORIES.
|
TRUE
FALSE |
|
WATER CONVEYS APPROXIMATELY _________ THE AMOUNT OF HEAT THAT STEAM CONVEYS.
|
A. 1/5
B. 1/4 C. 1/3 D. 1/2 |
|
A HOT WATER HEATING SYSTEM OPERATES AT _______________ THE STEAM HEATING SYSTEM.
|
A. A HGHER TEMPERATURE THAN
B. A LOWER TEMPERATURE THAN C. THE SAME TEMPERATURE THAN |
|
IN A NATURAL CIRCULATION HOT WATER HEATING SYSTEM, THE ________ FUNCTION AS A RELIEF VALVE.
|
A. SUPPLY LINE
B. RETURN LINE C. HEATING LINE D. EXPANSION TANK |
|
____________ PRESSURE IS WATER PRESSURE PER VERTICAL FOOT EXERTED AT THE BASE OF A COLUMN OF WATER.
|
A. NORMAL OPERATING WATER
B. ELECTROSTATIC C. HYDROSTATIC D. NONE OF THE ABOVE |
|
IN A REMOTE TEMPERATURE-MONITORING SYSTEM, THE BURNER IS CONTROLLED BASED ON ____________.
|
A. STEAM PRESSURE
B. TEMPERATURE OF AIR AT HEATING UNIT C. OUTSIDE TEMPERATURE D. MAKEUP WATER |
|
STEAM BOILERS ARE CLASSIFIED AS HIGH PRESSURE IF STEAM PRESSURE EXCEEDS ___________ PSI.
|
A. 7
B. 15 C. 20 D. 160 |
|
A FLOW CONTROL VALVE FUNCTIONS SIMILAR TO A(N) ____________ VALVE TO PREVENT NATURAL WATER CIRCULATION.
|
A. AIR SEPARATOR
B. PRESSURE REDUCING C. CHECK D. GATE |
|
HOT WATER BOILERS OPERATING WITH A 250 DEGREE WATER TEMPERATURE AND ______ PSI WATER PRESSURE OR LESS ARE CLASSIFIED AS LOW PRESSURE.
|
A. 10
B. 15 C. 100 D. 160 |
|
HOT WATER BOILERS CAN BE _________ BOILERS.
|
A. FIRETUBE
B. WATERTUBE C. CAST IRON SECTIONAL D. ALL OF THE ABOVE |
|
A HOT WATER BOILER SAFETY RELIEF VALVE IS RATED IN _________ RELIEVED PER HOUR.
|
A. BTU OF STEAM TEMPERATURE
B. POUNDS OF WATER PRESSURE C. POUNDS OF WATER TEMPERATURE D. NONE OF THE ABOVE |
|
A STEAM BOILER SAFETY VALVE IS RATED IN _________ RELIEVED PER HOUR.
|
A. BTU OF STEAM TEMPERATURE
B. POUNDS OF STEAM C. BTU OF WATER TEMPERATURE D. ALL OF THE ABOVE |
|
A SAFETY RELIEF VALVE MUST BE BUILT ACCORDING TO THE ___________.
|
A. ASME CODE
B. ABMA CODE C. BOILER MANUFACTURER SPECIFICATIONS D. NONE OF THE ABOVE |
|
THE RELIEVING PRESSURE OF A SAFETY RELIEF VALVE ON A LOW PRESSURE HOT WATER BOILER CANNOT EXCEED ________ PSI.
|
A. 15
B. 30 C. 160 D. 250 |
|
HOT WATER BOILERS USUALLY HAVE _______ PSI ON THE BOILER AT ALL TIMES.
|
A. 3 TO 5
B. 10 TO 15 C. 12 TO 18 D. 160 TO 250 |
|
THE _____ TANK IS NORMALLY HALF FULL OF WATER TO MAINTAIN THE CORRECT WATER LEVEL IN THE FORCED CIRCULATION HOT WATER HEATING SYSTEM.
|
A. EXPANSION
B. COMPRESSION C. RECEIVER D. VACUUM |
|
SECTION VI OF THE ASME CODE RECOMMENDS SAFETY RELIEF VALVES BE MANUALLY TESTED ___________.
|
A. ONCE A SHIFT
B. EVERY 24 HOURS C. EVERY 30 DAYS D. NONE OF THE ABOVE |
|
THE ________ PROTECTS THE HOT WATER HEATING SYSTEM FROM EXCEEDING THE MAWP.
|
A. AQUASTAT
B. BLOWDON VALVE C. SAFETY RELIEF VALVE D. COMPRESSION TANK |
|
THE _______ CONTROLS THE STARTING AND STOPPING OF THE BURNER BY SENSING THE TEMPERATURE IN THE HOT WATER BOILER.
|
A. FLOW CONTROL VALVE
B. DIVERTER FITTING C. CIRCULATING PUMP D. AQUASTAT |
|
THE TEMPERATURE-PRSSURE GAUGE INDICATES THE TEMPERATURE AND PRESSURE OF THE WATER _____________.
|
A. IN THE HEATING UNIT
B. LEAVING THE BOILER C. IN THE COMPRESSION TANK D. AT THE MIXING VALVE |
|
____________ DIRECT THE FLOW OF HOT WATER SUPPLIED TO AND RETURNED FROM THE HEATING UNITS.
|
A. FLOW CONTROL VALVES
B. HAND-OPERATED VALVES C. STEAM TRAPS D. DIVERTER FITTINGS |
|
A ____________ PREVENTS NATURAL CIRCULATION WHEN HOT WATER IS NOT BEING PUMPED THROUGH THE SYSTEM.
|
A. STOP VALVE
B. DIVERTER FITTING C. CIRCULATING PUMP D. FLOW CONTROL VALVE |
|
A PRESSURE-REDUCING VALVE REDUCES THE PRESSURE OF CITY WATER TO APPROXIMATELY _________ PSI.
|
A. 4 TO 6
B. 8 TO 10 C. 10 TO 15 D. 12 TO 18 |
|
A(N) __________ ALLOWS BLEEDING OF TRAPPED AIR IN A HEATING UNIT.
|
A. STEAM TRAP
B. DIVERTER FITTING C. AIR VENT D. AIR CONTROL |
|
IF THE COMPRESSION TANK IS ALLOWED TO FILL WITH WATER, PRESSURE WILL INCREASE, CAUSING THE ___________.
|
A. PRESSURE-REDUCING VALVE TO ACTIVATE
B. SAFETY RELIEF VALVE TO OPEN C. AIR CONTROL TO DRAIN THE WATER D. ALL OF THE ABOVE |
|
LARGER COMPRESSION TANKS ARE EQUIPPED WITH A _______ FOR DETERMINING THE COMPRESSION TANK WATER LEVEL.
|
A. SIGHT GLASS
B. TRY COCK C. GAUGE GLASS D. NONE OF THE ABOVE |