ICC/ANSI A117.1
|
# Accessible and Usable Buildings and Facilities - regulates the removal of barriers for the physically disabled
(Federal Regulation) |
|
Local Regulations
|
# amendments to the model building code in use
* relate to geographical region or helps to alleviate local problems; regulates local institutions and also the rules of the local fire departments |
|
Model Building Codes
|
instead of writing your own code per local jurisdiction (or state), most follow a model code
IBC is most popular |
|
IBC
|
# it is a consolidation of the the model codes previously published
* UBC (uniform building code) * the BOCA National Building Code (canada's primary code) * Standard Building Code (SBC) # IBC will eventually bring uniformity to the code across the country and replace all three |
|
ICC
International Code Council |
in 2003 the three codes merged
* UBC (uniform building code) * the BOCA National Building Code (canada's primary code) * Standard Building Code (SBC) |
|
Adjuncts to Building Codes
|
# companion codes that govern other aspects of construction; same group publishes these
* electrical code is used in all jurisdictions is the National Electrical Code (NEC) published by the NFPA. (so there is no section on electrical in the ICC) |
|
How are industry stds referenced in the ICC
|
they are made part by using the reference name and number and the date of the last revisions
|
|
Legal Basis of Codes
|
10th amendment of US Constitution, each state can then delegate these powers to the lower level municipalities
|
|
who is responsible for adopting and enforcing these codes
|
municipalities (or counties or districts)
|
|
who is ultimately responsible for making sure all design meets bc
|
design professional
|
|
NFPA
|
The National Fire Protection Association is a U.S. organization (albeit with some international members) charged with creating and maintaining minimum standards and requirements for fire prevention and suppression activities, training, and equipment, as well as other life-safety codes and standards. This includes everything from building codes to the personal protective equipment utilized by firefighters while extinguishing a blaze.
|
|
ASTM
|
# originally known as the American Society for Testing and Materials, is an international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems, and services.
* although ASTM does not actually perform the tests, writes the criteria on how to perform the tests for testing agencies |
|
NRTL
|
independent lab recognized by OSHA to test products to the specifications of applicable product safety standards
UL - e.g. Nationally Recognized Testing Laboratory |
|
ANSI
|
# is a private non-profit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States.
* ensure that the characteristics and performance of products are consistent, that people use the same definitions and terms, and that products are tested the same way. * also accredits organizations that carry out product or personnel certification in accordance with requirements defined in international standards. |
|
listed label
|
product passed the safety test
|
|
classified label
|
+ products are tested for certain types of uses only; must carry a statement specifying the conditions it was tested for
|
|
UL10B
|
most common UL is for Doors (Fire Tests for Door Assemblies)
|
|
Building Materials Directory
|
results of the UL tests and products that are listed are published in the UL...
|
|
ASTM E119
|
# Standard Test Methods for Fire Tests of Building Construction and Materials
* first measures heat transfer thru the wall, heats one side and tests how long it takes for the other side to combust * second is the hose stream - which uses a high pressure hose to see how long it takes to fall |
|
NFPA 253 (ASTM E648)
|
Floor Finishes (carpets, resilient floors and other floowing in corridors), FLOORING RADIANT PANEL TEST
Class I not less than .45 W/cm(hostpitals, facilties) & II not less than .22 W/cm (homes) |
|
ASTM D2859
|
Floor Finishes (carpets, and rugs), METHENAMINE PILL TEST
|
|
ASTM E119
|
floor/ceiling construction, fire ratings of walls structure, and floor construction assemblies, WALL & FLOOR/CEILING ASSEMBLY TEST
|
|
ASTM E84
|
wall finishes, flame-spread rating of finishes, STEINER TUNNEL TEST
|
|
NFPA 265 (similar to NFPA 286)
|
wall finishes, contribution of wall finish to fire growth in full-scale mockup, ROOM CORNER TEST
|
|
NFPA258
|
wall finishes, smoke developed from flaming and nonflaming solid materials, SMOKE DENSITY CHAMBER
|
|
UL10B (NFPA 252)
|
door/glass openings, endurance test of doors to flame and heat transfer, FIRE TESTS OF DOORS ASSEMBLIES
|
|
ASTM E163 (NFPA 257)
|
door/glass openings, endurance of glazing for 45 min to flame and heat transfer, FIRE TESTS OF WINDOW ASSEMBLIES
|
|
NFPA 260 (CAL TB 117)
|
furniture, separate fabric and fillings of upholstered furniture, CIGARETTE IGNITION RESISTANCE TEST OF FURNITURE COMPONENTS
|
|
NFPA 261 (CAL TB 116)
|
furniture, mock-up of a seat cushion, including foam liner, and fabric, CIGARETTE IGNITION RESISTANCE TEST OF FURNITURE COMPOSITES
|
|
NFPA 266 (CAL TB 133)
|
furniture, actual sample of a chair tetsted to an open flame, FULL SEATING TEST
|
|
NFPA 701
|
window coverings, draperies, curtains, as well as banners, awnings, VERTICAL IGNITION TEST
|
|
ASTM E662
|
+ Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials
# measures the amount of smoke given off by a flaming or smoldering material or finish # gives smoke density value from 0-800, most require 450 or less for finish materials |
|
continuous barrier
|
o must extend from the floor to the underside of teh floor or roof slab above or to the ceiling of a fire-resistance rated floor/ceiling or roof/ceiling assembly
|
|
fire partition
|
3/4 hour except for corridors - 20 min; (most commonly used) wall assembly with a fire-resistance rating of 1 hour, used in the following locations
* walls separating 'dwelling units' * walls separating guest rooms in Group R-1 occupancies, such as hotels, as well as R-2 and I-1 occupancies * walls separating tenant spaces in malls * corridor walls * EXCEPTIONS: corridor walls permitted to be non rated & dwelling and hotel rooms with sprinkler systems (then 1/2 hour) |
|
fire barrier
|
o (greater than 1 hour) vertical or horizontal assembly designed to restrict the spread of fire confine fire to limited area, and/or afford safe passage for protected egress
+ enclose vertical exits, passageway exits, horizontal exits, and incidental use area + separate different occupancies in a mixed-occupancy situation + separate single occupancies into different fire areas + must always be continuous from the floor slab to the underside of the floor or roof slab above |
|
smoke barrier
|
continuous vertical or horizontal membrane with a min. of one hour designed and constructed to restrict the movement of smoke (at least 20 minute rating for openings)
|