Nominal hydraulic system pressure is
3000psi
The accumulator in each hydraulic system function as
Pump pulsation dampers (precharged to 1500lbs)
Skydrol-B type hydraulic fluid is used in all hydraulic systems which is
Has fire retardant properties

Is highly corrosive

Is purple in color
The B hydraulic pumps normally operate
When the flaps are extended
pushing an ENG FIRE PUSH switchlight closes the hydraulic valve in the related
Engine driven A pump suction line
The No. 1 hydraulic system components are located in
Left side of the equipment bay
Pumps 1B and 2B are electrically supplied from
The offside main AC bus
When the 3B switch is selected to AUTO, the pump operates
If the flaps are extended and either IDG generator is offline
Fluid quantity limits are shown on the HYDRAULIC synoptic page by
Color coding of the numerical quantity readout within each reservoir (green-okay; white-too high or low)


Green lines shown vertically on each side of the reservoir symbols
The 3A hydraulic motor/pump assembly is located in the
Left side fuselage at the wing trailing edge
the priority valve in the No. 3 hydraulic system output manifold ensures
Adequate hydraulic pressure to the primary flight control PCUs
In normal operation with flaps extended, the system pressure readouts shown on the HYDRAULIC synoptic page indicate
The higher pressure produced between the A and B pumps
Failure of the hydraulic shutoff valve to close after the related ENG FIRE PUSH swithch is pused is indicated by
The related amber HYD SOV caution EICAS message
The amber HYD1 LO PRESS caution EICAS message indicates
Pumps 1A and 1B are not producing sufficient pressure (system pressure is low)
What alerting is activated if pump 1B produces 1900psi output
No alerting is activated
Filter clogging and subsequent fluid bypassing is indicated by
A red pin protruding from flush position on the related filter housing
If the 1B and 2B swithces are selected to ON while airborne, the 1B and 2B pumps
Are individually controlled to run only if the opposite generator is online
To ensure the 3B pump operates automatically after ADG deployment (no main AC Buses)
There are no cockpit controls that influence 3B pump operation, and the 3B swithch has no effect on pump operation when the ADG is deployed
If the APU or the IDG genterator(s) are recovered after ADG deployment, the 3B pump
May be transferred back to AC bus 1 by pushing the PWR TXFR OVERRIDE switch on the ADG panel