Central Station Certificate of Operation
|
F-40 (C of F for Operator of Central Station Signaling Systems)
|
|
Commercial Cooking Exhaust System Servicing Company Certificate
|
F-64/W-64 (C of F for Commercial Kitchen Exhaust System Cleaning Technician)
|
|
Fumigation and Thermal Insecticidal Fogging Operation Company Certificate
|
W-97 (C of F for Fumigation and Insecticidal Fogging) |
|
Portable Fire Extinguisher Servicing Company Certificate
|
W-96 (C of F for Full Service Shop) S-96 (Sales of Portable Fire Extinguishers) |
|
Smoke Detector Maintenance Company Certificate
|
S-97/S-98 (C of F for Fire Alarm Systems Inspection, Testing, and Service Technician) |
|
Torch Operation
|
G-60 (Torch Use of Flammable Gas) |
|
Decorations/Draperies and Curtains in Public Areas
|
C-15 (Flame Retardant Treatment)
|
|
Fire alarm systems
|
S-97/S-98 (C of F for Fire Alarm Systems Inspection, Testing, and Service Technician) |
|
Master Plumber who also holds a ____Certificate of Fitness are allowed to test, maintain, and repair/replace the standpipe systems that are NOT combined with sprinkler systems
|
|
|
What license does a technician need to repair a standpipe system combined with sprinkler systems in addition to possessing a S-12/S-13 C of F
|
Master Fire Suppression Piping Contractor license |
|
1. How frequently is a Standpipe hydrostatic pressure and flow test conducted? 2. Who performs the test? 3. Who else is present during the test? |
2. Master Fire Suppression Piping Contractor with a S-13 Certificate of Fitness 3. Representative of department and a building engineer, superintendent, or Fire Safety Director |
|
1. How frequently is a Sprinkler hydrostatic pressure and flow test conducted? 2. Who performs the test? 3. Who else is present during the test? |
1. Once every 5 years
2. Master Fire Suppression Piping Contractor with a S-12 Certificate of Fitness 3. Representative of department and a building engineer, superintendent, or Fire Safety Director |
|
A technician who is a Master Plumber and also holds the FDNY S-12 C of F are allowed to inspect, test, maintain, and repair/replace the sprinkler systems for the residential occupancies with ___Sprinkler heads or less without a booster pump. A. 100 B. 30 C. 31 D. 29 |
B. 30 |
|
The installation, alteration, testing, and repair of the sprinkler system, including any maintenance or modification of the system, shall be performed by a person possessing two licenses: (1) Certificate of Fitness for Citywide Sprinkler System (S-12) issued by FDNY and trained and knowledgeable in the installation, operation, and maintenance of the specific system (2) _______________ A. Master Plumber B. Master Fire Suppression Piping Contractor license issued by the New York City Department of Buildings |
B. Master Fire Suppression Piping Contractor license issued by the New York City Department of Buildings |
|
The programming, inspecting, testing, and servicing of fire alarm systems shall only be performed by______ Certification of Fitness holder(s). A. F-58 B. S-78/F-78 C. S-96 D. S-97/S-98 |
D. S-97/S-98
|
|
True or False: A S-97/S-98 Certificate of Fitness holder must be present at any FDNY Fire Alarm System test and inspection. |
True
|
|
True or False: A F-58 (FSD) Certificate of Fitness holder is allowed to perform the visual inspections, the monthly manual fire alarm activation test and maintain the log book. |
True
|