  • Front
  • Back
Exhaust Gas Temperature Limits
260 - 650
APU Starter Duty Cycle
1 minute ON / 4 Minutes OFF
If START LIGHT does not extinguish within 1 minute:
Move control switch to OFF/STOP and allow starter to cool for 4 minutes
APU Warm Up/Cool Down Time
Above 32 degrees: 1 minute W/U, 1 minute C/D
Below 32 degrees: 4 minute W/U, 1 minute C/D
APU RPM LIMIT
100% +/- 5%
Max 106%
Overspeed Autoshutdown 110%
APU Gen Limits
Freqs/Volts/Load
Freqs - 400Hz +/- 20Hz
Volts - 110v - 125v
Load - 0 - 1.05 amps
BOLDFACE
GROUND EMERGENCY PROCEDURES:
1.APU Fire Handle - Pulled (CP)
2.Fire Ext. - Discharge (as req'd)(CP)
a.If condition persists, discharge remaining bottle.
3.APU Gen. - OFF(FE)
4.Evacuate (refer to ground evac procedures) all
When APU fire handle pulled, the Apu is isolated as follows:
1.The Fuel shutoff valve and bleed air valve is closed.
2.The Fire extinguisher system directional flow valve is positioned for routing agent to the APU.
3.The extinguisher AGENT DISCHARGE switch is armed.
4.APU door closes.
Fire Bottle Pressure Limits and Reference
575-660 psi @ 70 degrees
NA 01-75GAA-6-2 Cards 20.1, 20.2
Fuel Requirements
2000lbs in #2 Tank -
If below 2000, turn on #2 Boost Pump
Exterior Pre-Turn Inspection
Remove Plugs and Covers
Grounding Wire
Fire Bottle
Aircon Oil Level
APU Oil Level
Battery Connected
Interior Pre-Turn Inspection
All Switches - off/safe/normal
Battery Voltage - 25vdc-30vdc
Radio Check - UHF or VHF
Check Warning Lights
Wing and Beaver Lights - Strobes