Condensate return-boiler feed water tank

Collects condensate from the system so it can be returned to the boiler
City water make up line

When condensate return tank level is low the city water make up line admits water to the tank to maintain minimum water level
Strainer

Strains out dirt and debris from the line. can be pulled apart and cleaned or blown down
Boiler feed water pump

Pumps water from boiler water feed tank through the Hartford loop to maintain water level in the boiler
Vent line
Prevents pressure build up or a vacuum from forming in the tank
Condensate return main

Returns condensate to the condensate return tank
Loop riser

Riser right before the Hartford Loop used to elevate the water to the tee that connects to the equalizing line
Concentric reducer

Reduces pipe size, keeps pipes on same center line
Equalizer-header drain connection

Connects the steam header to the boiler return connection equalizes supply pressure in the return line to the boiler
Loop riser

Feeds water to the boiler
Gate valve

Used for isolation
Pressure trol high limit with manual reset

Safety mechanism used to shutoff system if pressure goes above max pressure
Pressure trol subtractive differential operator

Starts and stops the boiler, set for min and max pressure
Control train

Header for pressure trols and gauges, keep steam from connecting instruments with condensate cushion, replaces pigtails
Clean out cross

Allows for inspection and cleaning of the control train
Pump control and low water cut-off

Activates the pump when boiler needs water, works in conjunction with pressure trols and boiler feed pump
Ball valve and blow down

Used for cleaning out the boiler
Secondary low water cut-off MM 67 with manual reset

If main low-water cut off fails it will kick off the boiler, will only turn back on with manual reset
Sight glass

Shows the water level in the boiler
Boiler drain

Used to drain the boiler
Swing check valve

Allows flow in one direction only. Position sensitive
Ball valve

Used to drain and clean strainer, isolation
Fast fill line

By passes the main header to quickly fill the boiler
Expansion tank

Air receiver, maintains constant minimum pressure
Expansion tank airtrol fitting

Release or add air to expansion tank
Prv - pressure reducing valve

Maintains minimum pressure
Float and thermostatic steam trap

Removes air and noncondensibles, returns condensate to the condensate return tank
Safety relief valve

Opens when pressure reaches max 30 psi and resets at 3 to 5 psi less than max
Shell and coil heat exchanger steam to water

Steam enters the shell and heats the water flowing through coils
Inline air separator

Removes entrained air bubbles from the water and sends them to the expansion tank
Dry well

Used to install a thermometer to test water temp
Balancing valve

Keeps gpm at nominal set point. Maintains proper amps
Steam supply line

Supplies steam to the heat exchanger
Hot water supply main

Supplies hot water to room units/system
Thermister

Changes the ohm resistance based on temperature. controls the outgoing water temp
Thermister

Changes the ohm resistance based on temperature. controls the outgoing water temp
Control panel

Houses all the controls and all the electrical of the hydronic system