The damage control organization is divided into how many parts?
2
What person coordinates the efforts of repair parties to control damage?
the damage control assistant
What are the duties of the administrative organization of damage control?
records and schedules for maintenance/ written doctrine and procedures relating to damage control/ ship's bills
What are the duties of the executive officer in regards to damage control
ship's survivability training/ readiness to manage casualties/ control and recover from damage
What officer is designated as the ship's damage control officer?
the engineer officer
The DCA is the primary assistant to the damage control officer. As such, the DCA has what responsibility?
administration of the ship's DC organization
What requirements must a petty officer have to be designated as the damage control petty officer (DCPO)?
Complete the PQS
Normally, the job of DCPO is held for what period of time?
6 months
What are the responsibilities of the DCPO?
assist in the instruction of division personnel in damage control/ prepare and maintain damage control checkoff lists for their spaces/ make required reports
What person is responsible for determining the safe entry of personnel into closed or poorly ventilated spaces?
the gas free engineer
What person is designated to aid the DCA train personnel and to prevent and fight fires?
the fire marshal
What action is taken if the fire marshal finds hazards that relate to poor housekeeping during a daily inspection?
submit discrepancy report to DCA with copies to XO and department head
The fire marshal has what responsibilities?
submitting reports citing hazards and recommendations for their correction/ setting up a fire watch team before regular overhauls
What is the purpose of the ship's damage control battle organization?
to restore the ship to as near normal operation as possible
In the damage control battle organization, what person is responsible for controlling damage; fighting fires; CBR countermeasures; and control of stability, list and trim?
the DCA
What are the primary damage control battle organization unit(s)
repair parties
What is the nerve center of the directing force for directing the damage control organization?
DCC or CCS
What repair party is in charge of main deck repair?
repair 1
What repair party is in charge of the propulsion repair?
repair 3
What repair party is in charge of electronic casualty control?
repair 8
Each repair party should be capable of performing what functions? (3)
rigging casualty power/ controlling flooding/ extinguishing all types of fires
When in port, the ship has what duty section components available to respond to any type of casualty?
in port emergency teams
The rescue and assistance detail must have what qualificaitons?
Be qualified as an emergency team member and be qualified in first aid
True or False. General Quarters is an all hands evolution-it is the highest state of readiness of the ship.
True
What is the correct GQ route to follow?
Aft in the passageways and down ladders on the port side
What system signals override microphone control stations to notify the ship's crew of imminent danger?
general announcing system
What type of communication system is X40J?
emergency damage control communications system
What alarm is sounded by the OOD or PreFly notifying ship's company of a pending or actual flight deck emergency?
flight crash
What alarm is sounded when there is a possibility that the ship will be struck by another waterborne unit?
collision alarm
When this alarm is sounded, all hands report to their preassigned stations and set material condition ZEBRA
general alarm
What means of communication is used when all other methods have failed?
messengers
All navy ships have how many material conditions of readiness?
3
What material condition provides the least degree of watertight integrity?
XRAY
What material condition sets the highest degree of watertight integrity?
ZEBRA
What fittings are closed when condition ZEBRA is set?
DOG Z fittings, Circle X fittings, and Y fittings
What means, if any is used by repair parties to find damage control fittings and closures in each compartment?
Compartment checkoff lists
The Damage Control Closure Log is maintained in what locations?
DCC and Quarterdeck
What log is a list of all DC-related fittings that don't work properly?
Inoperative Fittings and Closures Log
What fittings are secured when the ship is set for "darken ship"
DOG ZEBRA
The emergency escape breathing device (EEBD) supplies breathable air for what maximum period of time?
15 minutes
With training, you should be able to activate the EEBD within what maximum period of time?
30 seconds
What breathing device should NOT be worn for fire-fighting purposes?
SEED
What is the primary fire fighting tool for respiratory protection?
OBA
From the time it is activated, each cylinder used in the self-contained breathing apparatus (SCBA) will last approximately what length of time?
30 minutes
What substances must be present to start a fire?
heat, oxygen, and fuel
In the fire tetrahedron, how many components are neccessary for combustion?
4
Flammable materials give off vapors. What is the lowest temperature that these vapors burn when a spark is applied?
flash point
What term is used to describe the lowest temperature at which spontaneous combustion occurs?
ignition point
Heat from fire can be transferred by how many methods?
three
What method of heat transfer occurs when heat moves from one body to another by direct contact?
conduction
What method of heat transfer occurs through the motion of smoke, hot air, and heated gases?
convection
What type of heat transfer occurs when heat moves in all directions unless blocked?
radiation
What agents should be used to extinguish a class B fire?
water or AFFF
What agent should be used to extinguish class A or D fires?
water