  • Front
  • Back

What does ACOP stand for?

Approved Code of Practice

What Regulations should be referred to before starting on site projects?

CDM 2007



The Construction (Design and Management) Regulations 2007

What are the key aims of CDM 2007 Regulations?

To integrate Health & Safety into on site projects



To encourage everyone involved to work together

The CDM 2007 Regulations encourage everyone involved to work together to achieve what?

Improve planning and management



Identify hazards



Eliminate or manage hazards



Discourage unnecessary bureaucracy

When is a Construction Phase Plan needed?

When site projets involve higher risks

What personnel should be appointed to oversee issues on site?

CDM Co-ordinator

Site inductions should include what?

Senior Management commitment to health & safety



Outline of the project



Key personnel



Risks associated with the site



How risks are controlled

What does CITB stand for?

Construction Industry Training Board

What does CSCS stand for?

Construction Skills Certification Scheme

All workers are required to have what before working on site?

CSCS card



OR



CCNSG card



Awarded after passing a relevant health & safety tests

What does CCNSG stand for?

Client Contractor National Safety Group

What does ECITB stand for?

Engineering Construction Industry Training Board

Some equipment have an IP rating, what does that mean and what is it for?

Ingress Protection



OR also known as



International Protection Rating



The level of protection that equipment casings provide against particles and liquid

What are the three protection categories that IP codes use?

Solid Particle Protection - level 0-6



Liquid Ingress Protection - level 0-8



Other Protections - single letter

What additional letters are used for IP codes and what do they mean?


A – Back of hand


B – Finger


C – Tool


D – Wire


H – High voltage device


M – Device moving during water test


S – Device standing still during water test


W – Weather conditions

Some equipment have an IK rating, what does that mean and what is it for?

The level of protection that equipment casings provide against impact

What does NEMA stand for?

The National Electrical Manufacturer's Association

What is a NEMA rating?

The level of protection that equipment casings provide against various hazards



More varied and stringent than IP ratings

What is this device?

What is this device?

Earth Bonding Spike

What is the recommended clear woking space where there is exposed live parts at 400V AC?

915mm / 3 ft

What is the recommended clear woking space where there is exposed live parts of 400V AC exposed each side of the working space?

1375mm / 4 ft 6 ins



Screening should be used whenever possible

What is this device?

What is this device?

Voltage Detector (Multi-meter)

What are the most common accidents involving overhead power cables?

Handling long scaffold tubes



Handling long ladders



Operating cranes and other lifting plant



Raising tipper bodies etc.



Using Mobile Elevating Working Platforms (MEWPS)

What distance should vehicles, plant or equipment be kept from overhead power lines?

15 meters - from lines suspended from steel towers



8 meters - from lines suspended from wooden poles

What kind of hand tools should be used when working in a flammable environment?

Beryllium Bronze anti-sparking tools

Beryllium Bronze anti-sparking tools

110v equipment which is centre tapped to earth becomes what voltage?

55 V, which should eliminate the risk of death or injury

What precautions should be taken when welding on site

Protection Screens



Fire Blankets



Fire extinguisher



Sand or metal sheets to protect wooden floors



Fire blankets below when welding overhead



Assigned fire watcher with appropriate fire extinguisher

What height to base ratio should be used with mobile towers?

3:1



Outriggers can be used to increase base dimensions

What does MEWPs stand for?

Mobile Elevating Working Platforms

What does MCWPs stand for?

Mast Climbing Work Platforms

air in enclosed spaces must contain how much oxygen?

19.5 - 23.5%

Wht should extra care be taken when using oxyacetylene in confined spaces?

The oxyacetylene flame consumes oxygen from the environment as well as the cylinder



Operators should be observed at all times