the temperature of concrete may be mixed in a wheelbarrow? True or False
True
The Sensor of the temperature measuring device shall have at least ____ in. ____mm of concrete cover in all directions
3 in, 75 mm
The temp measuring device shall have a capacity of measuring temp of freshly mixed concrete to +/- ____ degrees F ____degrees C throughout a range of ____ to ___ degrees F (____to____degrees C.)
1* F (.5*C), 30*,120, [0, 50]
The temp measuring device shall be calibrated _____, or whenever there is a question of _____.
Annually; Accuracy
The temp of concrete may be measured in a wall form?
True
A composite sample of concrete is required even if teh only purpose for obtaining the sample is to determine temperature?
False
What must be done to the sample container prior to sampling the concrete?
Dampen (with water)
What must be done to the concrete surrounding the temp device after the device is submerged in the fresh concrete
Press the concrete around the temp device at the surface of the concrete
How long must the temp device remain in the freshly mixed concrete for an accurate reading?
2 minutes or until the temp reading stabilizes.
After the temp of the concrete is read, what is then required?
Recording of temp