what defines a WUI incident?
|
An incident where three or more structures are threatened by a wildfire
|
|
can a WUI alarm be an initial alarm?
|
know, it should be requested by command when several structures are threatened or a structure fire has wildland involvement that must be fought defensively
|
|
what is proper PPE for a WUI alarm
|
approved wildland PPE unless a structure becomes involved in the box alarm is set
|
|
in a WUI situation, what is the most vulnerable part of a structure?
|
The roof
|
|
what is the rule of thumb for the minimum defensible space from structure to brush in WUI situation?
|
30' from structure to flammable brush
|
|
what is the minimum lookout at a WUI alarm?
|
• Leader of each group be in constant contact with someone who can maintain full awareness of fire and weather conditions
• best if each group has at least one person acting as a lookout |
|
safety zone minimum times for WUI alarm:
|
safety zones should be no more than 2 min. travel time
|
|
additional WUI safety watch outs:
(10 items) |
• narrow one-way roads
• one way in or out • bridge load limits • inadequate water supplies • natural fuels 30' or closer • steep slopes • extreme fire behavior • strong winds • public panic |
|
structure protection for WUI alarms, apparatus minimums:
|
• structures less than 50' apart, one apparatus may cover 2 structures
• larger gap one apparatus for structure • larger than 5000 ft.², two apparatus for structure |
|
for WUI structure, combustible fencing should be removed for at least _____ where it connects to the house
|
8 feet at least
|
|
when laddering a structure on a WUI alarm what else should you do?
|
A line should also be stretched which can be used on the roof, if necessary
|
|
class A phone should be used to code structures plants and shrubs within a defensible space _____ minutes before expected arrival of fire front in a WUI alarm
|
15 min.
|
|
T/F: in a WUI alarm you should cut off all utilities including electricity and gas
|
false: gas should be shut off, electricity should be left on unless structure becomes involved
|
|
how should you prep a house during a WUI alarm?
|
• Close Windows
• remove combustible window coverings • closed interior doors • turn off fans and HVAC |
|
if a structure box alarm is called a WUI alarm, how should radio traffic be handled?
|
companies brought to seem for structure fire should be assigned to a group and given another fire ground channel
|
|
what size supply line should be used from the hydrant during a WUI alarm?
|
3 inch supply line if possible
|
|
if no hydrants available during a WUI alarm, name three other sources of water
|
• static water
• water tenders • Rotary wing aircraft |
|
what should be established if evacuation is being considered?
|
Community Services Group (CSG)
|
|
when conducting evacuation for a WUI alarm, ensure that structures are _____ for fire department access
|
left unlocked
|
|
when triaging a WUI alarm, what are three classifications to triage structures?
|
• Defensible
• defensible with some improvements • non-defensible |
|
one of the leading factors in structure loss during a wildland fire event is _____.
|
Fire brands
|
|
_____ can enter through very small openings on metal or tile roofs which are not sealed (gable vents and under these enriches)
|
sparks and embers
|
|
assigning a _____ group should be deemed a necessity at most large wildland fires
|
Downwind Exposure Group
|