Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
78 Cards in this Set
- Front
- Back
you are primarily concerned with ansering the question " how long does each step or group of steps take?" during which aircraft generation planning area?
|
aircraft gereration action timing
|
|
you are primarily concerned with ansering the question " what steps need to be take? during which aircraft generation planning area?
|
aircraft gern. actions
|
|
which af portal link can be used to access user manuals for variou af compter systers?
|
af center for electronic distrubution of systerm (AFCEDS)
|
|
which af portal link provides access to recurring af periodical like airman magazine and the air and space journal?
|
e-pubs
|
|
after initial triaininghow often much crashed, damaged, or disabled aircraft recovery (CDDAR) team members recieve additional academic and hands on training?
|
annually
|
|
how often must the team chief for the crashed, damaged or disavle aircrafdt recovery (CDDAR) program conduct a n exercise
|
annually
|
|
which maintenace squadron flight is the OPR for the MXGs CDDAR program operation instruction?
|
maintenance flight
|
|
the max total intial duty time including home station duty, travel time, and recovery site duty up arrival) that a maint. recovery team memver may be worked before being given 8 hours of uninterrupted rest is
|
16hrs
|
|
what af pub provides gerneral guidance for executin an effective maint. recovery operation?
|
21-101
|
|
a dropped object that has resultd in casualties or property damage must be reported IAW
|
afi 10-206, operational reporting
|
|
who is the QA chief inspector directly reponsible to for ensuring the req maint stand and eval program (MSEP) functins are performed?
|
qa oic
|
|
personel should normally be assigned to a unit for how many months before being selected as qa
|
6mos
|
|
what maint stand and eval team (MSET) individual assessment finding is defined as a condition that would endanger personnel or jeopardice equiment?
|
major
|
|
what main stand and eval team (MSET) individual assessment is performed after a completed task?
|
qvi
|
|
the wing fod monitor must notify the majcom fod manager within how many hours of a fod incident?
|
24
|
|
what dollar amount of damage must be exceeded for a fod incident to be used to calculate the fod rate for a unit
|
$20,000
|
|
what time-frame is used for determining whether an item that fallls off an a/c is considered a reportable dropped object?
|
engine start to engine shut down
|
|
who appoints an nco as the mxg aircraft structural intergrity team project officer?
|
mxg commander (MXG/CC)
|
|
what amu section is req to ensure aircraft stuctural integrity program (ASIP) equppied a/c are identified as such in weekly schedules?
|
P N S
|
|
who is the office of primary responsibity for develpoment of wing procedures for control and management of tools/equip. used on the flt line and in industrial areas?
|
mxg/cc
|
|
in addition to daily accountabilty checks, how often must support conduct and document a mxg/cc standariz inspection of all support section tools and equip.
|
annually
|
|
how many digits make up an equipment id designator code used on tools
|
9
|
|
without a waiver, what is the min postiion an individual must hold before clearing a red X for a lost tool that has NOT been found
|
mx supt
|
|
if a serially controlled item is canned, who is the cann authorty req to notify
|
P N S
|
|
for a unit using the extended cann cycle, the standard time frame for having an a/c down is
|
45-60 days
|
|
how are radiographic inspections accomplished outside the NDI lab classed?
|
unshielded
|
|
when calibratin nav. equip. an external power unit is attached while towing an a.c during what type of operation
|
compass rose
|
|
during a red ball, it is importat that expediter have a qrl availabe in order to
|
reduce the time needed to research parts
|
|
who is not a member of the "joint council on aging aircraft"?
|
national trans safety board
|
|
units cannot make local mods to which af pub?
|
TOs
|
|
who is responsible for estab. a mxg to custodain to administer to req in support of assigned group missions and activiees
|
mxg/cc
|
|
what is not normally a mxg todo duty
|
sub-accounts
|
|
the product improvement manager is usually assigned to what mxg section
|
qa
|
|
which of the following is NOT a to change priorty cat.
- urgent, routine, standard, emergancy |
standard
|
|
an improvment that ids a replacement for haz materials or an ozone depleting substance would be submitted as what to change priorty
|
urgent
|
|
who is the final approval authorty for waivers of to system policeies and procedures
|
A4MM
|
|
what is NOT an approved commucation method for issuing approved to waiver or deviaitn
|
telephone
|
|
what agency is normally responsble for monitoring the overall maint. supply interface and resolving support probs.
|
MSL
|
|
which of the following is not normally MSL duty
|
collecting and turing in precious metals
|
|
the assets in a high priorty mission support kit should be transferred into the host base standard base supply system account after how many days
|
30
|
|
how often are opertin commands req to review permanent readiness spares packages?
|
annually
|
|
which expendabitily, recoverability, and reparability codes must be assigned to an asset before it can be placed on bench stock
|
xb3
|
|
shop stock should NOT exeed how days of use
|
90
|
|
provided it is still servicealbe, you are allowd to inspect and remark with a new expiration date which type of shelf life item
|
II
|
|
who is responsible for developing a HAZCOM training plan to notify personeel of all know hazards they may be exposed to
|
section supervisor
|
|
who in the mxg is responsible for ensuring the capabiltiy exists to meet local manufacture reqs
|
mx supt
|
|
who must appoint an individual to be an equipment account custodian?
|
squadron commander
|
|
an individual must recieve what specific block of supply training before assuming duties as a DIFM monitor
|
IIB
|
|
which precious metal indicator code indicates that an item of supply does not contain precious metal?
|
A
|
|
which precious metal indicator code indicates that an item of supply conains a combo of two or more prec. metals?
|
C
|
|
whcih supply tracking doc provides info on all doc numvbers processed druing the day
|
D04, DAILY doc reg
|
|
which supply tracking doc is produced daily and lists all back ordered parts with an urgencey code of A
|
D18, Priority (urgent) mont. report
|
|
which supply tracking doc provides a management product for monitoring issue and bench stock supply support?
|
M24, organization effectivness report
|
|
which LRS office accounts for special purpose recoveravle authorized maint. (SRPAM) assets managed on in use detail records
|
ELO
|
|
what is the special purpose recoveravle authorized maint. (SPRAM) flag code for stand alone spares?
|
A
|
|
what is the SPRAM flag code for fault iso. spares
|
F
|
|
who is the final authority fo reviewing a units list of supply assets req. functional check, calibration or operational flt. programming?
|
LRS Chief Inspector
|
|
which of the following is NOT normally in the review chain for items listed as supply assets requring locally performed funct. check, calibration,
|
mxg/cc
|
|
who ultimatley deternmine if the secruty provided at a TA location is adequate for classified assets installed on an a/c
|
aircraft commander
|
|
when the aircraft owner or user does not stay with their aircraft, they musst arrange for securty checks to be accomplished every
|
3 hrs
|
|
what supply delivery priority is appropriatte for primary mission a.c 13 hrs after landing
|
3
|
|
what supply delivery priority is appropriate for bench stock req
|
5
|
|
which urgency justification codes are used to show a supply request for bits and pieces to repair a line replaceable unit or shop replaceable unit spare
|
AR or BR
|
|
before a supply point can be established and located in a maintenance work area, who must Maintence coordinate with?
|
LRS material management
|
|
what is the accountabiliy document used for supply points that shows the quantity authorized, on-hand, and due out?
|
supply point listing
|
|
when a mission capable part issues and is placed in TNB supply ppl notify
|
MOC
|
|
when a backordered part issues and is placed in TNB supply ppl notify
|
P N S
|
|
when items are placed in an a.c. TNB, which entry is NOT normally needed
|
security class
|
|
when the goal is to get a refund or a new item in exchange, what type of deficiency report is submitted?
|
supply discrepency report
|
|
who has the responsibility for overall deficiency report program management for the submitting organization or group
|
originating point
|
|
who acts as the deficiency report focal point between the support point and submitting organization
|
action point
|
|
in order to account for unfunded req and vaild non-maint tasks, the logistics composite model allows what percentage of overhead manning
|
10
|
|
which element of a logistics compostie model study considers weather modeling condition
|
operations req
|
|
whcih factor is not modeled in a logistics composite model manpower study
|
training deployment
|
|
manpower authorizations are
|
funded
|
|
a unit manpower document (UDM) does not
|
show the name of person assigned to a particular position
|
|
a meeting to discuss manning issues in the MXG is normally held
|
monthly
|
|
which MXG office acts as the OPR for maintenanace analysis referrals
|
MDSA (analysis)
|