What is the primary source of DC power when on the ground and the engines are not running?
|
24-26v batteries
|
|
Selection of the three-position switch to BAT 1 prompts reading of the:
|
Left battery amperage
|
|
The battery reverse current relay opens if there is a:
|
250 amp continuous reverse current
|
|
When the battery reverse current relay opens due to a reverse current of 250 amps, it causes the associated:
|
1. BAT switch to trip
2. BAT light to illuminate |
|
Where are the batteries located?
|
Rear compartment
|
|
The HOT BAT light comes on when the battery temperature reaches what temperature?
|
150 deg F
|
|
What preliminary warning is given to indicate the battery is getting hot?
|
Amber WARM light illuminates
|
|
How is it possible to indicate an approximate battery temperature on the battery temperatue indicator if the temperature is less than 100 deg F?
|
Depress the LESS 50 pushbutton
|
|
What systems are directly supplied from the battery bus?
|
Mod center lighting, pressure refueling, fire extinguishing, and service lights
|
|
When the EXT POWER pushbutton is depressed:
|
Both batteries #1 and #2 are isolated.
|
|
If the generator fails (trips), what action is required to reset its output?
|
Move the generator switch to ON
|
|
Which engine generators supply electrical power to the main left DC bus?
|
#1 and #2
|
|
What generators supply power to the main right DC bus?
|
#3 and APU
|
|
Where is the grd power receptacle?
|
On right aft side of the fuselage
|
|
What voltage is required from a ground power unit?
|
28v DC
|
|
How is grd power applied to the airplane?
|
By pressing the EXT PWR pushbutton
|
|
When grd power is connected and selected, which lights illuminate?
|
BAT 1, BAT 2, GEN 1, GEN 2 and GEN 3
|
|
When you need to Shed electrical power, what items do you turn off?
|
1. Tranfer Pumps
2. Side Window Heat 3. Galley Power |
|
When will a generator switch trip?
|
D- Dead Short
O- Over voltage R- Reverse Current M- Mechanical |
|
The bus tied relay receives its power from:
|
Both RH and LH bus
|
|
What is the normal voltage and overvoltage?
|
Normal- 28.5v Overvoltage- 32v |
|
What is the max output for the generators?
|
350 amps for 1 min 300 amps when FL 390 and below 250 amps when above FL 390 |
|
What does the GCU do after the start?
|
GCU will reduce generator voltage after start (-1v) for 3 min to soft charge the batteries.
|
|
What items will drop a generator off line?
|
D- Dead Short- trips the generator switch O- Over Voltage- at 32V, trips the generator switch R- Reverse Current- trips the battery switch M- Mechanical |
|
|
|