WHAT IS THE A/C FFIGHTING AND RESCUE DAILY JOURNAL
A CHRONOLOGICAL LISTING OF ALL PERTINENT EVENTS MAINTAINED BY EACH A/C FFIGHTING AND RESCUE ORGANIZATION
WHAT IS THE RETENTION PERIOD OF THE AC FFIGHTING AND RESCUE DAILY JOURNAL
THREE YEARS AFTER THE JOURNAL IS COMPLETED
WHAT IS THE FUNCTION OF TANK TRUCKS
THEY ARE USED TO RESUPPLY PRIMARY FFIGHTING AND RESCUE VEHICLES WITH LIQUID AGENTS FOR EXTENDED PERIODS OF OPERATION
WHAT IS THE FUNCTION OF THE STRUCTURAL FIRE PUMPERS AND BRUSH FIRE TRUCKS
THEY ARE USED TO BACK UP AC FFIGHTING AND RESCUE TRUCKS AND SHOULD BE EQUIPPED WITH AFFF
WHAT IS THE MINIMUM RESPONSE REQUIREMENT FOR A CAT 1 AIRFIELD CRASH CRANE
PERSONNEL AND EQUIPMENT MUST ARRIVE AT THE SCENE OF AN AC MISHAP ON THE AIRFIELD WITHIN 15 MINUTES AFTER NOTIFICATION, BY A SENIOR AC SALVAGE SUPERVISOR, OF THE INTENT TO LIFT/SALVAGE A MISHAP AC
WHAT IS THE MINIMUM RESPONSE REQUIREMENT FOR A CAT II PUBLIC WORKS CRANE
PERSONNEL AND EQUIPMENT MUST ARRIVE AT THE SCENE OF AN AC MISHAP ON THE AIRFIELD WITHIN 45 MINUTES AFTER NOTIFICATION, BY A SENIOR AC SALVAGE SUPERVISOR, OF THE INTENT TO LIFT/SALVAGE A MISHAP AC
WHAT IS THE CREW REQUIREMENT TO OPERATE A RESCUE VEHICLE
2 PERSONS
WHAT IS THE CREW REQUIREMENT TO OPERATE A TANK TRUCK
2 PERSONS
WHAT IS THE CREW REQUIREMENT TO OPERATE A 530-C
3 PERSONS
WHAT IS THE PURPOSE OF THE IMMEDIATE RESPONSE ALERT (FIXED WING AC)
TO PROVIDE IMMEDIATE RESPONSE TO OBSERVED UNANTICIPATED EMERGENCIES AND TO CONTROL ANY FIRES UNTIL THE STANKBY ALERT TEAM CAN EFFECT RESCUE AND FIRE EXTINGUISHMENT
WHAT IS THE MAX AMOUNT OF IMMEDIATE RESPONSE ALERT DUTY A PERSON IS ALLOWED TO PERFORM IN ANY 24 HOUR PERIOD
NO MORE THE 8 HOURS
WHAT MAY BE USED WHERE AC GROSS TAKEOFF WEIGHT IS 10,000 POUNDS OR LESS AS THE IMMEDIATE RESPONSE ALERT IN LIEU OF A MAJOR EMERGENCY FFIGHTING AND RESCUE VEHICLE
A TRUCK MOUNTED TAU WITH A CREW OF 3 PERSONS
WHAT IS THE STANDBY ALERT CRITERIA
IT IS MAINTAINED TO PERMIT ARRIVAL AT THE SCENE OF AN EMERGENCY WITHIN THREE MINUTES
WHAT IS THE WATER STORAGE TANK CAPACITY OF THE P-4A FFIGHTING AND RESCUE TRUCK
1,500 GALL
HOW IS THE AFFF CONCENTRATE AND WATER MIXED PRIOR TO BEING DISCHARGED
IT IS MIXED IN THE VENTURI INDUCTORS
HOW MANY FEET OF HOSE IS PROVIDED IN THE HANDLINE OF THE P4A RESCUE TRUCK
150 FT
WHEN BOTH THE ROOF TURRET (750 GPM) AND THE BUMPER TURRET (250 GPM) ARE OPERATING ON THE P4A, HOW LONG DOES IT TAKE BEFORE THE TRUCK DEPLETES ITS SELF CONTAINED WATER SUPPLY
1 1/2 MINUTES
HOW IS THE P-15 FFIGHTING TRUCK AND PUMPING SYSTEM POWERED
BY TWO 8 CYLINDER DIESEL ENGINES, ONE FORWARD AND ONE REAR MOUNTED
WHAT IS THE MAX DISCHARGE FLOW RATE FROM THE HANDLINE ON A P-15 FFIGHTING VEHICLE
100 GPM
WHAT IS THE WATER STORAGE TANK CAPACITY OF THE P-15
6,200 GALLONS
WHAT FFIGHTING VEHICLE HAS OFF ROAD CAPABILITY AND WILL CLIMB AN 18 INCH WALL OR ASCEND OR DESCEND A 60% GRADE
THE 1000
WHAT IS THE WATER STORAGE TANK CAPACITY OF THE P19 FFIGHTING AND RESCUE TRUCK
1,000 GALL WITH A FOAM TANK HOLDING 1300 GALLONS
WHAT ARE THE TWIN AGENT UNITS
A SERIES OF FIRE EXTINGUISHERS THAT ALL ARE DUEL AGENT APPARATUS DESIGNED PRIMARILY FOR EXTINGUISHING CLASS B FIRES AND ARE NORMALLY EMPLOYED ABOARD SHIP AT HOT REFUELING SITES, OR AS A TRUCK MOUNTED TAU
HOW DOES THE TAU FIRE EXTINGUISHER AFFECT A FIRE
THE PKP ACTS AS AN EXTINGUISHING AGENT AND THE LIGHT WATER ACTS AS A VAPOR MOUNTED TAU
WHAT IS THE STANDARD AGENT CAPACITY FOR THE MOBILE TAU
80 GALLONS OF AFFF PREMIXED SOLUTION AND 100 POUNDS OF CHEMICAL AGENT
WHAT ARE THE WATER TANK AND AFFF TANK CAPACITIES FOR THE AMERTEK CF 4000L
WATER IS 1050 GALL WITH THE AFFF TANK HOLDING 156 GALL
WHAT IS THE EFFECTIVE RANGE, IN FEET, OF THE ROOF TURRET ON THE AMERTEK CF 4000L
175 FT
WHAT IS THE EFFECTIVE RANGE IN FEET OF THE BUMPER TURRET ON THE AMERTEC CF 4000L
150 FT
WHAT OTHER FFIGHTING AGENT IS ALSO AVAILABLE ON THE AMERTEK CF 4000L
500 LBS OF HALON 1211
WHAT IS THE WATER STORAGE TANK CAPACITY OF THE T-3000 OSHKOSH
3000 GALLONS
WHAT IS THE DISCHARGE RATE OF THE ROOF TURRET ON THE T-3000 OSHKOSH
600-1200 GPM AND A VARIABLE PATTERN FROM STRAIGHT STREAM TO FULLY DISPERSED
WHAT IS THE DISCHARGE RATE OF THE BUMPER TURRET ON THE T3000 OSHKOSH
300 GPM AND IS ALSO VARIABLE PATTERN
THE ASSIGNMENT AS DRIVER/OPERATOR OF MAJOR EMERGENCY AC FFIGHTING AND RESCUE EQUIPMENT SHOULD BE MADE FOR WHAT LENGTH OF TIME
2 YEARS
WHAT IS THE EXPERIENCE GOAL FOR EQUIPMENT DRIVER ASSIGNMENTS
AT LEAST 1/2 OF THE ON-DUTY PERSONNEL SHOULD HAVE A MIN OF 8 MONTHS EXPERIENCE IN THE ASSIGNMENT
WHAT IS THE RESERVE STOCK FOR EACH MANNED APPARATUS FOR EACH CRASH AND FFIGHTING ORGANIZATION
AT LEAST TWO AGENT TANK LOADS OF AFFF AND ONE LOAD OF HALON 1211 AND PKP
WHAT ARE THE PRIMARY FLIGHT LINE EXTINGUISHERS
150 LB, WHEELED, HALON 1211 FIRE EXTINGUISHERS
HOW OFTEN SHOULD ALL PERSONNEL ENGAGED IN AC RELATED OPERATIONS BE TRAINED BY THE FIRE DEPARTMENT IN THE OPERATION OF ALL EXTINGUISHERS IN SERVICE ON THE AIRFIELD
AT LEAST ANNUALLY
HOW OFTEN SHOULD FIRE EXTINGUISHERS BE INSPECTED PER LOCAL FIRE DEPARTMENT INSTRUCTIONS
DAILY
WHAT ACTION MUST BE TAKEN WHEN A FIRE EXTINGUISHER IS REMOVED FROM ITS ASSIGNED LOCATION TO BE RECHARGED
IT MUST BE REPLACED BY AN EQUIVALENT SPARE EXTINGUISHER DURING THE PERIOD OF REMOVAL
WHAT IS THE RETENTION PERIOD FOR THE RECORDS OF REQUIRED EXTINGUISHER MAINTENANCE
MINIMUM OF ONE YEAR
WHAT SHOULD BE DONE WHEN AN EXTINGUISHER SHOWS EVIDENCE OF CORROSION OR MECHANICAL DAMAGE
MUST BE SUBJECTED TO A HYDROSTATIC PRESSURE TEXT ACCORDING TO THE NFPA FIRE CODES, STANDARD NO. 10
WHAT HAPPENS WHEN A PORTABLE EXTINGUISHER IS USED AT TOO CLOSE RANGE
THE FIRE MAY BE SCATTERED
WHAT CLASS OF FIRES ARE HALON 1211 EXTINGUISHERS USED FOR
PRIMARILY ON CLASS B AND C FIRES, BUT THEY ARE ALSO EFFECTIVE ON CLASS A FIRES
HOW ARE HALON 1211 EXTINGUISHERS MARKED
A REFLECTIVE 6-INCH SILVER BAND AROUND THE TANK
WHY SHOULD YOU NOT USE HALON ON CLASS D FIRES
IT HAS NO BLANKETING EFFECT, AND SHOULD IT REACH A CLASS D FIRE IN THE LIQUID STATE, THE POSSIBILITY OF AN EXPLOSIVE REACTION EXISTS
HOW SHOULD THE INITIAL APPLICATION OF HALON BE MADE
AS CLOSE TO THE FIRE AS POSSIBLE, WITH THE DISCHARGE DIRECTED AT THE BASE OF THE FLAMES
WHAT IS THE PRIMARY TYPE OF FIRE OFOR USING THE CO2 EXTINGUISHER
CLASS B AND C FIRES
HOW ARE THE CO2 EXTINGUISHERS MARKED
WITH A 6 INCH YELLOW REFLECTIVE BAND AROUND THE TANK
HOW SHOULD CO2 EXTINGUISHERS BE APPLIED TO A FIRE
SHOULD COMMENCE AT THE UPWIND EDGE AND BE DIRECTED SLOWLY IN A SIDE TO SIDE SWEEPING MOTION, GRADUALLY MOVING TOWARD THE BACK OF THE FIRE
THE PKP EXTINGUISHERS ARE PRIMARILY DESIGNED FOR WHAT TYPE OF FIRE
CLASS B
HOW ARE PKP MARKED
WITH A 6 INCH PURPLE BAND
HOW SHOULD PKP BE USED ON FLAMMABLE LIQUID FIRES
NOT BE DIRECTED AT THE BASE OF THE FLAME AND GRADUALLY MOVED TOWARD THE BACK OF THE FIRE WHILE THE MOZZLE IS SWEPT RAPIDLY FROM SIDE TO SIDE
WHO IS RESP FOR PLACEMENT, TIMELY INSPECTION, MAINTENANCE, RECHARGING OF ALL FIRE EXTINGUISHERS, AND THE TRAINING OF FLIGHT LINE PERSONNEL IN THE USE OF PORTABLE FIRE EXTINGUISHERS
STATION FIRE CHIEFS
WHAT IS THE CORRECT METHOD TO STORE ALUMINIZED PROT CLOTHING
ON HANGERS WITH SUITABLE HANGING SPACE TO PREVENT THE FABRIC FROM CREASING OR CRACKING
(IF GARMENTS ARE FOLDED THEY ARE FOLDED LOOSELY)
HOW SHOULD PPV BE CLEANED
DIRT AND SOOT SHOULD BE SPONGED OFF WITH MILD SOAP AND WATER, AND THE ALUMINUM SURFACE DRIED WITH A CLEAN CLOTH. RUB IT GENTLY TO AVOID REMOVAL OF THE ALUMINUM
HOW SHOULD THE GOLD COATED FACEPIECE BE CLEANED
CLEAN IT WITHOUT REMOVING FROM THE HOOD BY USING A CLEAN SOFT CLOTH WITH MILD SOAPY WATER, THEN RINSE AND PAT DRY
WHAT ALLOY IS APPROXIMATELY 1/2 AS HEAVY AS STEEL AND ALMOST AS HARD AND IS USED AS SHEETS FOR SKIN SURFACE AS CHANNELS FOR FRAMEWORK AND AS PLATES AND CASTINGS FOR BULKHEADS AND FITTINGS
ALUMINUM ALLOY
WHY IS IT ESSENTIAL TO KEEP FUSELAGE SKIN SURFACES COOL WHERE ALUMINUM ALLOY IS USED UNTIL RESCUE OPS ARE COMPLETED
IT WILL NOT WITHSTAND HEAT OR FLAME EXPOSURE, BECAUSE IT MELTS UNDER THE CONDITIONS FOUND IN AIRCRAFT FIRES
WHAT ALLOYS ARE USED FOR LANDING GEAR AND WHEELS, ENGINE MOUNTINGS, BRACKETS, CRANKCASE SECTIONS, COVERPLATES AND OTHER ENGINE PARTS
MAGNESIUM ALLOYS
WHAT IS THE PROBABLE EFFECT OF PROLONGED EXPOSURE TO HIGH TEMPS ON MAGNESIUM AC STRUCTURES
INTENSE BURNING
WHAT METAL WHICH PRESENTS NO FIRE HAZARD, IS USED IN ENGINE PARTS, AROUND ENGINE NACELLES TO INCREASE THE FIRE RESISTANCE OF THE NACELLE, FOR ENGINE "FIREWALLS" AND FOR TUBING AND STRUCTURAL FRAMING ON FABRIC AC
STEEL
WHAT IS TEH PRINCIPAL HAZARD PRESENTED BY TITANIUM WHERE IT IS USED IN AC
ITS FRICTION SPARK HAZARD IN CASES WHERE THE METAL IS EXPOSED TO CONTACT WITH A PAVED SURFACE
WHAT IS COLORBANDING USED ON AC PLUMBING AND ELECTRICAL WIRING
COLORBANDING IS USED TO IDENTIFY THE VARIOUS PLUMBING SYSTEMS, TO AID IN THE INSTALLATION AND MAINTENANCE OF AC
WHAT SYMBOL IS USED ON AC PLUMBING THAT CARRIES COLLANT
HORIZONTAL "S"
WHAT SURFACE OF A PARTIALLY FILLED WING FUEL TANK WILL MOST LIKELY RUPTURE IF THE TANK EXPLODES DURING A FIRE
THE TOP
WHERE WOULD U LOOK FOR THE EXACT LOCATION OF FUEL TANKS ON A PARTICULAR AC
00-80R-14-1
WHY IS THE HYDRAULIC FLUID SYSTEM OF AIRCRAFT A CONCERN TO THE CRASH CREW
BECAUSE THE LINES MAY RUPTURE; THE BRAKES COULD RELEASE; AND THE HIGH PRESSURE CONTAINED IN SOME LINES MAY HARM CREW MEMBER WHEN CUT
WHAT IS THE PRINCIPAL FIRE HAZARD FROM THE ELECTRICAL SYSTEM ON AC
THE DANGER OF A SHORT CIRCUIT OR ACRCING OF THE SYSTEM
WHY IS LIQUID OXYGEN EXTREMELY DANGEROUS
IT BOILS INTO GASEOUS OXYGEN AT -297 F
WHO SHOULD PROVIDE U WITH THE MOST INFO ABOUT THE HAZARDS OF ARMAMENT CARRIED BY THE AC AT YOUR PARTICULAR STATION
INSTRUCTORS IN THE TRAINING PROGRAM FOR THE CRASH CREW
WHAT ARE THE PRIMARY HEALTH HAZARDS OF HYPERGOLIC MATERIALS
CHEMICAL BURNS, POISONING, AND FROSTBITE
WHAT IS TEH BEST WAY TO FIGHT FIRES INVOLVING HYPERGOLIC MIXTURES
DILUTE THE FUEL AND OXIDIZER WITH LARGE QUANTITIES OF WATER
WHAT IS THE FLASH POINT OF HYDRAZINE
126 F
WHAT IS THE FIRST STEP TO TAKE IF LIQUID HYDRAZINE IS SPLASHED IN THE EYES OR ON THE SKIN
FLOOD WITH WATER FOR 15 MINUTES AT A MINIMUM, AND SEEK MEDICAL CARE. IMMEDIATELY REMOVE CONTAMINATED CLOTHING. IF ODOR OF AMMONIA IS PRESENT, REMOVE PERSONNEL TO FRESH AIR AREA, AT LEAST 100 FT UPWIND OF THE AIRCRAFT
IN WHAT SITUATION ARE ROCKETS EXTREMELY DANGEROUS
WHEN THEY ARE STILL ON THEIR LAUNCHERS
WHAT IS THE ESTIMATED TIME PERIOD NEEDED TO HEAT A ROCKET TO AUTOIGNITION TEMP WHEN DIRECTLY EXPOSED TO A FUEL FIRE OF APPROX 1,500F
15 MINUTES
WHAT IS USUALLY THE RESULT OF A PROPELLANT
A SPLIT MOTOR TUBE
WHAT IS THE DETERMINING FACTOR FOR POST AC FIRE OVERHAUL SALVAGE EVENTS TO BEGIN
THEY MAY NOT START UNTIL ALL WEAPONS HAVE BEEN DETERMINED SAFE OR REMOVED BY EXPLOSIVE ORDNANCE DISPOSAL PERSONNEL
WHAT ARE PYROTECHNICS
FIREWORKS DESIGNED FOR SIGNALS, WARNINGS, LIGHTING FOR PHOTOGRAPHY, BOMBING OR LANDING, OR OTHER SPECIAL PURPOSES
HOW SHOULD THE MK 45 OR LUU-2 BE EXTINGUISHED
INSERT A WATER APPLICATOR TIP INTO THE BURNING END OF THE CANDLE AND APPLY LOW VELOCITY FOG ( THE FLARE NORMALLY EXTINGUISHES IN LESS THEN 30 SECONDS)
WHAT ACTION MAY BE TAKEN TO EXTINGUISH A MK 45 OR LUU-2 CANDLE WHEN A FOG APPLICATOR ISN'T READILY AVAILABLE
HAVE SOMEONE WHO IS FULLY OUTFITTED WITH A HOT SUIT CUT THE SHROUD LINES, PICK UP THE FLARE BY THE COLD END, AND JETTISON IT OVER THE SIDE OR REMOVE IT TO A CLEAR AREA IF IT IS ASHORE
WHAT IS THE CORRECT WAY TO HANDLE A BATTERY THAT IS EMITTING SMOKE, FUMES OR ELECTROLYTE IN THE ABENCE OF FLAME OR FIRE
MAKE SURE THE BATTERY SWITCH IN THE COCKPIT IS IN THE OFF POSTION, REMOVE THE QUICK DISCONNECT FROM THE BATTERY AND IF POSSIBLE MOVE THE BATTERY CLEAR OF THE AC. USE WATER FOG TO LOWER THE BATTERY TEMP
WHAT TOXIC SUBSTANCE COULD BE RELEASED FROM SONOBOUYS WITH DAMAGED LITHIUM BATTERIES
SULFUR DIOXIDE GAS
WHAT FIRE EXTINGUISHER AGENTS SHOULD NOT BE USED ON BURNING LITHIUM
HALON, PKP OR CO2
AT WHAT TEMP WILL EPOXY BINDER IGNITE OR DECOMPOSE
APPROX 752 F
WHY SHOULD U NOT ATTEMPT TO WASH AWAY PIECES OF VITON WITH WATER OR AFFF
IT COULD INCREASE THE DANGER OF CORROSIVE RESIDUES
WHAT IS THE MOST SIGNIFICANT RADIOLOGICAL HAZARD ASSOCIATED WITH A MISHAP INVOLVING NUCLEAR WEAPONS CONTAINING PLUTONIUM
INHALATION OF ALPHA PARTICLES