All single occupancy cell shall contain...

A minimum of 35 square feet of unencumbered floor area.

All multiple occupancy sleeping units shall contain...

A minimum of 25 square feet of unencumbered floor space per inmate.

Each single and multiple occupancy sleeping unit shall be equipped with the following:

1. A steel detention type bunk for each occupant which is securely fastened to the floor or wall and can accommodate a standard fire retardant mattress.



2. A toilet and lavatory with drinking font, serviceable from outside the cell.



3. A steel shelf area for personal items.



4. An unbreakable mirror securely mounted.



5. A writing surface affixed to the wall with a proximate area to sit.



6. Detention type ventilation and exhaust grills and registers.

Depending on the size of the facility, one or more isolation, detention cell shall be constructed to detain violent inmates.

1. A minimum of 70 square feet in floor space area.



2. A metal bunk affixed to the wall or floor.



3. A security tamper-proof recessed light.



4. A stainless steel toilet and lavatory sanitary unit serviceable from outside the cell.

Cell and multiple occupancy sleeping unit walls shall...

Shall be at least six-inch reinforced concrete or eight-inch concrete block containing vertical reinforcement rods.

Cell and multiple occupancy sleeping ceilings shall...

Shall be pre-cast concrete plank or reinforced concrete and shall be a minimum of eight feet in height.

Multiple occupancy sleeping units in new and existing facilities shall...

Have no less than two inmates and no more than 64 inmates per unit. Each unit shall have a minimum of 25 square feet of unencumbered floor space per inmate, a minimum ceiling height of eight feet and adequate space for lockers.

Doors of cells and multiple occupancy sleeping units shall...

Shall be detention type hollow metal with a vision port of security glazing and secured with a detention type locking device. Where deemed appropriate, food passes shall be installed.

The minimum ratio of toilets, wash basins and mirrors in multiple occupancy sleeping units shall be:

1. One toilet for every 12 inmates in male sleeping units (one half of these toilets may be urinal).



2. One toilet for every eight inmates in female sleeping units.



3. One operable wash basin with hot and cold running water for every 12 inmates.



4. One unbreakable mirror per wash basin.

All facilities shall have day rooms. And shall contain 35 square feet of floor space per inmate, exclusive of lavatories, showers and toilets, for the maximum number of inmates who can use the day room at one time.

The day room area shall be separate and distinct from the sleeping area, but immediately adjacent and accessible there from. Exterior light and view shall be provided.

A qualified inmate with a disability shall be housed in a manner that provides for his or her safety, security and accessibility to facility programs and activities.

Rooms, sleeping units, shall be designed for use by qualified inmates with disabilities.